![Intimus INT-GU-05280EPSHP Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/intimus/int-gu-05280epshp/int-gu-05280epshp_operation-manual_2081565048.webp)
Operation Manual 5280 EPSHP
48
8.1.2.7 Slightly unscrew the first screw on the left side of the clamping screw 2 (Fig. 31),
taking care that the screw head does not protrude above the knife beam sliding plane.
8.1.2.8 Press the "Change knife" function on the programmer 3 (Fig.22)
8.1.2.9 Pressing the push buttons 2
(Fig. 33) at the same time, start the cutting cycle.
The knife will stop in the lower position.
8.1.2.10. Switch off the power supply of the electrical system by turning the main switch knob
3 (fig. 33) to the "0" position
Figure 32a
8.1.2.11. Screw in the bolt 2 lightly (fig.32a)
Figure 33
8.1.2.12.Remove (loosen) the fixing screws 4 (fig.33) so that the knife falls under its own
weight on the base bar with its entire length.