Figure 18 Operating elements when used during pressing.
7.5.2 Change of clamping force
Changes in the clamping force are made by the knob 1, reading the pressure value on the
pressure gauge 4 (Fig.18)
- turning to the right - increasing the pressure
- turning to the left - reducing the clamping force
Approximate values of the clamping force depending on the pressure value read on
the pressure gauge (manometer) 4
•
25 bar ~ 200 daN
•
40 bar ~ 400 daN
•
55 bar ~ 600 daN
•
70 bar ~ 800 daN
•
90 bar ~ 1000 daN
•
110 bar ~ 1200 daN