![Intimus INT-GU-05280EPSHP Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/intimus/int-gu-05280epshp/int-gu-05280epshp_operation-manual_2081565032.webp)
Operation Manual 5280 EPSHP
32
Set the main switch 1 to "ON" 1 position (Fig. 15)
1. Press the green button 2 (Fig.15)
- green LED 3 on the program unit 6 display lights up (fig.15)
- the green OSSD 1 LED lights up (Fig.11) in the receiver 4 (Fig.15)
Figure 16 Safety curtain
1. Transmitter
2. Receiver
A - field of the security curtain
7.3.2 Diagnostics of the safety curtain after switching on the power supply.
When the cutter is switched on, the transmitter 1 and receiver 2 are initialized (fig. 16). All
transmitter and receiver LEDs will light for a moment. After initialization the receiver indicates
the quality of the setting using four blue LEDs 3 (Fig.11). (Table 9)
The setting indicator extinguishes after a suitable time when the safety light curtain is set (the
LED of the device switching the output signal: green item 1 figure 11) and only the PWR LED
of transmitter 1 (fig.12) and LED 1 (fig. 11) device for switching the receiver´s output signal.
In case of an error on the device, the red LED will light. On the side receiver red error LED -
in combination with blue LEDs -indicates the cause of the error.
DANGER!
In case of malfunction of photocells, immediately contact the service!