background image

(189IO)  MODEL CS7221/CS7231  SALTWATER SYSTEM & FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  07/11/2012

189A

    SAVE THESE INSTRUCTIONS

English

Page 14

SALT 

POOL 

WATER 

VOLUMES

SALT & POOL WATER VOLUMES

•  Which kind of salt to use:

Use only Sodium Chloride Salts

Use only sodium chloride (NaCl) salt that is at least 99.8% pure. It is also   

acceptable to use water conditioning salt pellets (the compressed forms of   

evaporated salt). However, it will take a longer time for them to dissolve. 

Do not 

use iodized or yellow (yellow prussiate of soda) colored salt. 

Salt is added to 

the pool water and the electrolytic cell uses the salt to create the sanitizer. So, the 

purer the salt the better the performance of the electrolytic cell.

•  Optimum Salt Levels

The ideal salt level in the pool water is between 2500-3500 ppm (parts per million). 

The optimal level is 3000 ppm.

A too low salt level will reduce the efficiency of the saltwater system and result in 

low sanitizer production. A high salt level may generate a salty taste to the pool 

water (this may occur at a salt level above 3500-4000ppm). Too high of a salt level 

may damage the power supply and cause corrosion to pool metal fixtures and 

accessories. The Salt Table page of this manual, shows the correct dosage of salt 

needed. The salt in the pool is constantly recycled. Salt loss occurs only when pool 

water is physically removed from the pool. Salt is not lost due to evaporation.

•  Adding Salt

1

.  Switch on the unit, then press and hold both      and      button for 5 seconds,  

 

the LED flashes “FP”. The unit is now in a Filter pump working mode and    

 

switch the filter pump on to start the water circulation.

2

.  Keep the Saltwater System turned off.

3

.  Determine the amount of salt to be added (see “Salt Table”).

4

.  Evenly spread the proper amount of salt around the inside perimeter of the    

 pool.

5

.  Avoid clogging the filter by not adding salt through the skimmer.

6

.  Brush the pool bottom to speed up the dissolving process. Do not allow salt to  

 

pile up on the bottom of the pool. Run the filter pump 24 consecutive hours to  

 

thoroughly dissolve the salt.

7

.  After 24 hours and if all the salt is dissolved, turn on the Saltwater System,    

 

press      button until you hear a “beep”, code “00” flashing (see “System    

 

Operation” section steps 2 to 4) and set the saltwater pool system to desired  

 

operating time (see “Operating Time Table”).

•  Removing Salt

If too much salt has been added, the unit will beep and display “Code 92” (see “Alarm 

Codes”). You will need to lower the salt concentration. The only way to do so, is to 

partially drain the pool and refill it with fresh water. Drain and refill 

approximately 20% of the pool’s water until the “Code 92” disappears.

•  Pool Volume Calculation

      

Rectangular

 

Length x Width x Average Depth x 7.5 

Length x Width x Average Depth

         

 Circular

 

Length x Width x Average Depth x 5.9 

Length x Width x Average Depth x 0.79

          

  Oval

 

Length x Width x Average Depth x 6.0 

Length x Width x Average Depth x 0.80

 Types of Pool

 Gallons

(pool size in feet)

Cubic Meters

(pool size in meters)

Содержание Krystal Clear CS7221

Страница 1: ...eting Ltd Intex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits réservés Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprimé en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilisées dans certains pays sous licence de Marcas registradas utilizadas en algunos p...

Страница 2: ... Salt Pool Water Volumes 14 Intex Pools Salt Table 15 Intex Pools Cyanuric Acid Table 16 Intex Pools Operating Time Table 17 Non Intex Pools Salt Table 18 Non Intex Pools Cyanuric Acid Table 18 Non Intex Pools Operating Time Table 18 Operating Instructions 19 21 LED Code Chart 22 Stationary Mounting 23 Maintenance 24 27 Long Term Storage 27 Pool Maintenance and Chemical Definitions 28 Troubleshoot...

Страница 3: ...the product The plug must be accessible after produc t is installed Do not bury the electrical cord Locate the cord where it will not be damaged by lawn mowers hedge trimmers and other equipment If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard To reduce the risk of electric shock do not use extension c...

Страница 4: ...FILTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 07 11 2012 189A SAVE THESE INSTRUCTIONS English Page 4 PARTS LIST PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale 4 5 6 7 9 8 10 11 12 13 14 15 2 3 1 16 17 18 ...

Страница 5: ...PANTONE 295U 07 11 2012 189A SAVE THESE INSTRUCTIONS English Page 5 NOTE Drawings for illustration purpose only Actual product may vary Not to scale PARTS LIST PARTS LIST continued 19 20 21 22 23 24 25 26 27 34 37 28 29 30 Optional Optional Optional Optional 31 32 35 33 36 38 ...

Страница 6: ...TIONS English Page 6 PARTS REFERENCE PARTS REFERENCE Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 1 2 3 4 6 5 8 8 7 1 2 10 9 37 13 14 15 12 16 17 30 38 18 11 31 32 35 36 ...

Страница 7: ...English Page 7 PARTS REFERENCE PARTS REFERENCE continued Before assembling your product please take a few minutes to check the contents and become familiar with all the parts 19 20 21 22 23 24 25 19 20 21 26 27 28 19 20 21 22 23 24 19 20 21 26 27 29 NOTE Drawings for illustration purpose only Actual product may vary Not to scale ...

Страница 8: ...1 11460 12 ELECTROLYTIC CELL NUT 1 11582 13 ELECTROLYTIC CELL O RING C INCLUDED 1 11578 14 COPPER ELECTRODE 1 11579 15 L SHAPE O RING 1 11228 16 O RING C 1 10717 17 ANGLE JOINT O RING D INCLUDED 1 11584 18 O RING A 1 11587 19 PLUNGER VALVE HOSE O RING STEP WASHER INCLUDED 2 10747 20 HOSE O RING 10262 21 STEP WASHER 10745 22 STRAINER NUT 2 10256 23 FLAT STRAINER RUBBER WASHER 2 10255 24 THREADED ST...

Страница 9: ...slightly salty The pool water flows through the saltwater system s electrolytic cell to produce HCLO The HCLO dissolves in the water and instantly starts destroying bacteria and algae It also oxidizes all other organic materials Low voltage direct current is applied to the copper electrode and copper ions are generated and dissolved instantly in the water Copper is an effective algaecide which wil...

Страница 10: ...epicted in the Parts List section of this manual To install do the following 1 Grasp the strainer and plunger valve mechanism 2 In a counter clockwise motion unscrew plunger valve union from the threaded strainer connector 24 Be careful not to lose the step rubber washer 21 3 Grasp the plunger valve assembly Make sure the step washer 21 is in place Connect adaptor B 26 to plunger valve union 4 Rep...

Страница 11: ...the flat washer 23 on the connector 24 3 Install the strainer and plunger valve at the lower position of pool outlet marked From the inside of the pool liner insert the connector 24 into one of the pre cut holes with the washer remaining on the connector to be placed against the inside of the liner wall 4 Before assembly lubricate the threads with a petroleum jelly Then with the flat side of the s...

Страница 12: ...e threads with a petroleum jelly Then with the flat side of the strainer nut 22 facing the outside wall of the liner in a clockwise motion screw the strainer nut 22 back onto the threaded connector 24 see drawing 6 5 Finger tighten the adjustable pool inlet nozzle 25 and the strainer nut 22 onto the threaded connector 24 6 Grasp the plunger valve assembly Make sure the step washer 21 is in place 7...

Страница 13: ...connect the hose nuts to the Saltwater System Filter Pump 4 In a counter clockwise motion unscrew the threaded filter housing collar 3 from the filter housing Place it in a safe place 5 The Saltwater System Filter Pump is an airtight system In a counter clockwise motion turn both air release valves 1 7 1 2 turns to open DO NOT remove air release valves as water will expel with force if the motor i...

Страница 14: ... lost due to evaporation Adding Salt 1 Switch on the unit then press and hold both and button for 5 seconds the LED flashes FP The unit is now in a Filter pump working mode and switch the filter pump on to start the water circulation 2 Keep the Saltwater System turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly spread the proper amount of salt around the inside perimeter...

Страница 15: ...x122cm 16 x48 4273 16173 110 50 30 15 488cmx132cm 16 x52 4614 17464 115 50 30 15 549cmx107cm 18 x42 4786 18115 120 55 30 15 549cmx122cm 18 x48 5455 20647 135 60 35 15 CIRCULAR METAL FRAME POOL 457cmx91cm 15 x36 3282 12422 80 35 20 10 457cmx107cm 15 x42 3861 14614 100 45 25 10 457cmx122cm 15 x48 4440 16805 110 50 30 15 488cmx122cm 16 x48 5061 19156 125 55 35 15 549cmx122cm 18 x48 6423 24311 160 75 ...

Страница 16: ...Cyanuric Acid Needed for Startup 0 03g L 30ppm Gals Liters Lbs Kgs INTEX ABOVE GROUND POOLS AGP s EASY SET POOL 457cmx84cm 15 x33 2587 9792 0 6 0 3 457cmx91cm 15 x36 2822 10681 0 7 0 3 457cmx107cm 15 x42 3284 12430 0 8 0 4 457cmx122cm 15 x48 3736 14141 0 9 0 4 488cmx107cm 16 x42 3754 14209 0 9 0 4 488cmx122cm 16 x48 4273 16173 1 1 0 5 488cmx132cm 16 x52 4614 17464 1 2 0 5 549cmx107cm 18 x42 4786 1...

Страница 17: ...4209 4 4 5 488cmx122cm 16 x48 4273 16173 4 5 6 488cmx132cm 16 x52 4614 17464 5 5 6 549cmx107cm 18 x42 4786 18115 5 5 6 549cmx122cm 18 x48 5455 20647 6 6 7 CIRCULAR METAL FRAME POOL 457cmx91cm 15 x36 3282 12422 3 4 5 457cmx107cm 15 x42 3861 14614 4 4 5 457cmx122cm 15 x48 4440 16805 5 5 6 488cmx122cm 16 x48 5061 19156 5 6 7 549cmx122cm 18 x48 6423 24311 7 7 8 ULTRA FRAME POOL 488cmx122cm 16 x48 5061...

Страница 18: ...03 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 0008 CYANURIC ACID TABLE FOR COMMON NON INTEX POOLS Water Capacity Salt Needed for Startup Salt Needed when Low Salt Detected CODE 91 Gals Liters Lbs Kgs Lbs Kgs 2000 7500 50 20 10 5 4000 15000 100 45 25 10 6000 22500 150 65 40 20 7000 26500 175 80 55 20 Water Capacity Operating Time hours at different ambient air temperatures Gals Liters 1...

Страница 19: ...er tighten the valves in a clockwise direction 5 Turn on the switch The filter pump is now filtering the water 6 The green Pump light on the control panel will light up that indicates the filter pump is running To prevent air lock open the lower plunger valve connected inlet hose first and then the upper plunger valve connected outlet hose Open air release valves lift and lower the inlet hose unti...

Страница 20: ...ter System at the same time each day for the number of hours you have set NOTE The Saltwater System will not operate if the filter pump is not operating 3 Lock keypad controls With the desired hour value showing press button until you hear a beep The green WORKING indicator on the control panel will light up within a few seconds to indicate that the saltwater system has started sanitizer productio...

Страница 21: ...orine is between 0 5 3 0 ppm and copper ion concentration is between 0 1 0 2 ppm When the copper level is below 0 1 ppm repeat step 6 NOTE A High copper ion concentration may cause blonde hair to exhibit a green hair To prevent this wear a swimming cap during swimming and wash hair with special shampoo after using the pool See Troubleshooting Guide 8 Stand by power saving mode When the cycle ends ...

Страница 22: ... remaining 04 Operating Hours 4 hours remaining 05 Operating Hours 5 hours remaining 06 Operating Hours 6 hours remaining 07 Operating Hours 7 hours remaining 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining 90 Alarm Code Low Pump Flow No Flow 91 Alarm ...

Страница 23: ...ea regarding above the ground swimming pool filter pumps If yes then the product can be mounted to a platform using the two holes located in the base See drawing below The product can be mounted on a cement base or onto a wooden platform to prevent accidental falling over Total assembly must exceed 18kg The European norm EN 60335 2 41 requires this product be secured to the ground or to a base 1 T...

Страница 24: ...4 After the flow sensor has been inspected and cleaned align the locator notch on the flow sensor to the connection ridge in the conduit Now turn the collar in a clockwise motion tightening the sensor back into its position Do not overtighten The electrolytic cell 13 has a self cleaning function incorporated into the electronic control s programming In most cases this self cleaning action will kee...

Страница 25: ...ater System and assemble the cell cover 30 at the side of the cell 4 In a counter clockwise motion unscrew the collar of the copper electrode 14 and remove it from the electrolytic cell 13 Lift up the copper electrode 5 Pour kitchen grade vinegar into the cell to immerse the titanium plates Then put the copper electrode back in the cell soak them for about one hour until no colored areas remain 6 ...

Страница 26: ...e inside of the filter housing 8 If dirt or sediment is located on the bottom of the housing then A In a counter clockwise motion gently unscrew and remove the sediment valve 1 located at the bottom of the housing Place it in a safe place B With a bucket of water or a garden hose pour water into the housing flushing out the sediment C Screw back the sediment valve 1 in a gentle clockwise motion Do...

Страница 27: ...ly 2 Hold the strip level for 15 seconds Do not shake excess water from the strip 3 Now compare the strip pad to the color chart on the packaging label If necessary adjust the chemical level in the pool water It is very important to use the proper technique when testing the water s chemical level Read and follow the written strip instructions carefully 1 Disconnect the power cord from the electric...

Страница 28: ... cloudy water eye skin irritation poor Chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved in the water Result if too high Scale will form and will cause the water to become cloudy Stabilizer Stabilizers extend the life of Chlorine in swimming pools Cyanuric Acid Consult with local swimming pool dealer for water treatment HCLO A very effective killer of alg...

Страница 29: ...d by a Class A Ground Fault Circuit Interrupter or RCD Reset circuit breaker If circuit breaker trips repeatedly your electrical system may have a defect Turn off circuit breaker and call an electrician to correct the problem Let motor cool down Adjust the sanitizer and pH level Consult your local swimming pool supply stores Clean or replace cartridge Check the cartridge for holes Replace if damag...

Страница 30: ...ter using the test strips If the pool is clean and clear add stabilizer to the water and then test the water with the device running Increase operating time per day See Operating Instructions Use PH decrease chemical to adjust contact your local pool chemical store Increase the operating time per day See Operating Instructions Remove the cell for inspection clean it if necessary See Maintenance Co...

Страница 31: ...nd the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the flow sensor firmly into the flow sensor receptacle Reset both timers on the filter pump and saltwater system See Boost Cycle Contact Intex Service Center Remove the electrolytic cell for inspection Clean it if necessary See Maintenance Add s...

Страница 32: ...er all risks and dangers For additional safeguards also familiarize yourself with the following general guidelines as well as guidelines provided by nationally recognized Safety Organizations Demand constant supervision A competent adult should be appointed as a lifeguard or water watcher especially when children are in and around the pool Learn to swim Take the time to learn CPR and first aid Ins...

Страница 33: ...oted above please contact the appropriate Intex Service Center listed in the separate Authorized Service Centers sheet The Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES OR LIABILITIES So...

Отзывы: