FILTER PUMP OPERATION
OPERATING
INSTRUCTIONS
1
. Make sure the unit is switched off. The switch is located on the control station.
2
. Connect the power cord to a GFCI/RCD protected electrical outlet.
3
. Turn both plunger valve handles fully counter-clockwise until they stop. This
opens the valve, allowing water to flow into the filter pump.
4
. With water flowing into unit, the water pressure will allow the air trapped inside
to escape from the air release valves
(1 & 7)
. When all the air has escaped
water will flow out of the valves
(1 & 7)
. When this occurs gently finger tighten
the valves in a clockwise direction.
5
. Turn on the switch. The filter pump is now filtering the water.
6
. The green "Pump" light on the control panel will light up, that indicates the filter
pump is running.
To prevent air lock, open the lower plunger valve (connected inlet hose)
first and then the upper plunger valve (connected outlet hose). Open air
release valves, lift and lower the inlet hose until water starts to flow out of
the air release valves, close air release valves.
IMPORTANT
WARNING
Risk of electric shock. Connect this product only to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI) or residual
current device (RCD). Contact a qualified electrician if you cannot verify
that the receptacle is protected by a GFCI/RCD. Use a qualified electrician
to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a
portable residual current device (PRCD).