V-PAC inverter heat pumps 

VPT 12, 16, 22

Owner Installation Manual 1005759 Issue 3

Summary of Contents for VPT Series

Page 1: ...V PAC inverter heat pumps VPT 12 16 22 Owner Installation Manual 1005759 Issue 3...

Page 2: ...s This appliance can be used by children from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision...

Page 3: ...CKS 15 3 6 ELECTROLYTIC CORROSION IN SWIMMING POOLS 16 3 7 ELECTRIC WIRING AND SUPPLY 16 3 8 CONNECTING THE HEAT PUMP TO THE POWER SUPPLY 17 3 9 POOL PUMP OVERRIDE TERMINALS P1 P2 18 4 0 USING YOUR HE...

Page 4: ...he heat pump Please read and follow all safety advice The refrigerant used in this heat pump is R32 This refrigerant is environmentally friendly but safety instructions must be strictly adhered to The...

Page 5: ...the following location requirements must be ful lled The heat pump must be kept away from sources of re or naked ames The heat pump must be installed operated and stored where the oor area is larger t...

Page 6: ...ms can damage electronic equipment Ideally the heat pump should be switched o at the mains HEAT PUMP MALFUNCTION WARNING Isolate heat pump electrically and wait 3 minutes before removing panels or ent...

Page 7: ...rants may not contain an odour Appliance shall be installed operated and stored in a room with a oor area larger than Xm2 where X is the minimum area shown in section 3 2 and section 8 0 The heat pump...

Page 8: ...e heat pump upright Do not lift the heat pump by the water inlet or outlet connections If this is done the titanium heat exchanger inside the heat pump could be damaged 2 2 ACCESSORIES These accessori...

Page 9: ...AND RANGE Air temperature operating range V PAC VPT X models 5 43 C Water temperature setting range Heating 18 C 40 C Cooling 12 C 30 C 2 5 OPERATING MODES The heat pump has three modes Powerful mode...

Page 10: ...energy from the air drawn through it To function e ectively the heat pump must have access to the fresh air it needs Air must not recirculate The air leaving the heat pump must not be sucked back into...

Page 11: ...ee areas m2 Model Discharge area VPT 12 0 188 VPT 16 0 188 VPT 22 0 220 Required free areas to provide air ow to and from heat pumps when installed in an enclosed area or where required to pass air th...

Page 12: ...WNER INSTALLATION MANUAL To comply with safety regulations regarding electrical installations in wet areas the heat pump must be installed at least 350cm away from the edge of the pool or spa 350 cm S...

Page 13: ...s below their lower ammability limit LFL European standard EN378 de nes requirements to remain far below the lower ammable limit in case of accidental leakage By choosing the location as dictated by E...

Page 14: ...tiser fitted Non return valve Sanitiser or chemical dosing device If fitted Aux heater If fitted Filter Pump To waste for winterising drain down 100mm Condensate water to waste Spare port for winteris...

Page 15: ...ater in Supported pipework 3 5 INITIAL CHECKS Start the ltration pump before the heat pump is turned on and turn o the heat pump before the ltration pump It is recommended to turn o the heat pump prio...

Page 16: ...his includes non electrical items such as metal lters pump strainer boxes heat exchangers steps and handrails It is highly recommended that bonding be retro tted to existing pools which may not be pro...

Page 17: ...y 230V 50Hz Supply cord Distribution box L N RCD Circuit Breaker P1 P2 Power terminals Pump terminals Cable clamp Single phase Terminals in Heat Pump Electrics enclosure Isolator which disconnects all...

Page 18: ...and the heat pump runs the pool lter pump for temperature sampling and if the pool subsequently requires heating cooling This feature operates by over riding the timeclock whenever the controller mea...

Page 19: ...icator light Powerful Smart Silent M S T 88 88 Silent mode indicator light Power HEAT COOL Heating indicator light Timer on indicator light Timer off indicator light Cooling indicator light Powerful S...

Page 20: ...ay e Defrosting 1 Automatic defrosting When machine is defrosting the heating indicator lamp ashes after defrosting the ashing stops 2 Forced Defrosting When machine is heating and the compressor has...

Page 21: ...to adjust these Press M again to and it will now show the timer o time Adjust these in the same way as the timer on Once complete press M to save the setting h Cancel timer There are two ways to cance...

Page 22: ...will sound twice and all parameter values will change back to their default values QUERY CODE MEANING RANGE 1 Water inlet temperature 20 99 C 2 Water outlet temperature 20 99 C 3 Ambient temperature...

Page 23: ...supply immediately then contact your dealer The fuse blows frequently or leakage circuit breaker trips frequently If above solutions don t work please contact your installer with detailed information...

Page 24: ...p will resume standby once process is completed 3 Er 21 Ambient temperature is out of range either lower than 5 C or higher than 43 C If outside wait for ambient conditions to improve winterisation ma...

Page 25: ...exhaust gas temperature alarm Er 15 Water inlet temperature sensor failure Er 16 Evaporator coil temperature sensor failure Er 18 Exhaust gas temperature sensor failure Er 19 DC fan motor error Er 20...

Page 26: ...Check bolts cables and connections regularly Repair service and disposal of redundant heat pumps must be completed by authorised technicians It is illegal to allow refrigerant gases to escape to air D...

Page 27: ...Rated input current A 1 21 8 9 1 23 12 0 3 45 19 6 Maximum input current A 12 5 15 5 24 5 Rated RCD type F mA 30 30 30 Rated Fuse aM MCB type C A 16 20 32 Sound level at 10m dB A 29 30 30 Recommended...

Page 28: ...N VPT12 ALX 650 98 362 650 626 220 835 600 92 490 190 430 588 130 VPT16 ALX 650 98 362 650 626 220 835 600 92 490 190 430 588 130 VPT22 ALX 752 138 387 745 721 240 967 695 92 530 228 505 705 157 F I B...

Page 29: ...provide frost protection To eliminate corrosion problems To inhibit electrical components 1 Switch o electrical supply to heat pump 2 Remove external fuses and keep in safe place away from heat pump...

Page 30: ...nd duct pressure are outside the speci ed limits 9 The air ow to and from the machine is outside the speci ed limits If in doubt or if advice is required please contact the Dantherm Group UK Service D...

Page 31: ...31 1005759 ISSUE 3 12 0 DECLARATION OF CONFORMITY...

Page 32: ...Dantherm Ltd Unit 12 Galliford Road Maldon CM9 4XD United Kingdom 44 0 1621 856 611 sales uk dantherm com Calorex is a brand of danthermgroup co uk...