background image

(307IO)  HEAT PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  12/15/2016

English

307

IO

SAVE THESE INSTRUCTIONS

English

Page 22

REF. NO.

DESCRIPTION

REF. NO.

DESCRIPTION

1

 TOP COVER

26

 EXHAUST PIPE

2

 TOP FRAME

27

 HIGH PRESSURE PROTECTION SWITCH

3

 AMBIENT TEMPERATURE SENSOR

28

 RETURN PIPE

4

 AMBIENT TEMPERATURE SENSOR CLIP

29

 LOW PRESSURE PROTECTION SWITCH

5

 DISTRIBUTOR SETS

30

 SUCTION VALVE

6

 BACK GRID

31

 BASE TRAY

7

 EVAPORATOR

32

 TITANIUM EXCHANGER

8

 PILLAR

33

 PLUG

9

 LEFT SIDE GRID

34

 COLLECTION PIPE SETS

10

 FAN MOTOR STAND

35

 WATER INLET RUBBER RING (BLUE)

11

 ELECTRIC BOX COVER

36

 RIGHT SIDE PANEL

12

 FAN MOTOR

37

 ELECTRIC CABLE CONNECT

13

 FAN BLADE

38

 PIPE (EXCHANGER TO CAPILLARY)

14

 LOGO

39

 PRESSURE GAUGE

15

 FRONT PANEL

40

 WATER FLOW SWITCH

16

 FRONT GRID

41

 WATER OUTLET RUBBER RING (RED)

17

 TRANSFORMER

42

 UNION

18

 COMPRESSOR CAPACITANCE

43

 PIPE (EXCHANGER TO CAP NUT)

19

 ELECTRIC BOX

44

 BACK PANEL

20

 ISOLATED PANEL

45

 CONTROLLER HOLDER

21

 MAIN BOARD

46

 ELECTRIC CABLE CONNECT

22

 FAN MOTOR CAPACITANCE

47

 WATER PROOF CONTROLLER BOX (WITH SEAL RING)

23

 FIVE POSITION TERMINAL BLOCK

48

 CONTROLLER

24

 CLIP

49

 WIRING COVER

25

 COMPRESSOR

SERVICE BY QUALIFIED TECHNICIANS (continued)

Содержание HP6220

Страница 1: ...ntex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used...

Страница 2: ...TIONS English Page 2 Warnings 3 4 Parts Reference 5 6 Product Specifications 7 Set Up Instructions 8 12 Display Control Panel Operation 13 Maintenance 14 Pool Water Chemistry 14 Heat Pump Caring 15 Tr...

Страница 3: ...embly by adults only Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Position this product away from pool to prevent a child from climbing on produc...

Страница 4: ...supervision or instruction concerning use of the heat pump by a person responsible for their safety The heat pump doesn t work at air temperatures below 8 C Disconnect the power cable from the electr...

Страница 5: ...ote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 L SHAPE O RING 6 11228 2 HEAT PUMP FITTING NUT 2 12567 3 38MM HOSE ADAPTOR 6 12571 4 HEAT PUMP 50MM PIPE ADAPTOR 2 12555 5...

Страница 6: ...e parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 15...

Страница 7: ...e drop 14 kPa Operating water temperature range 15 C 35 C Operating air temperature range 8 C 40 C Class of protection I Type of protection IPX4 Heat exchanger Titanium inside a PVC reservoir Compress...

Страница 8: ...tion containers The heat pump must be fixed and installed on a flat solid vibration free and level support cement slab or prefabricated platform Do not install the heat pump on unstable ground To redu...

Страница 9: ...le discharge area Water Connection and Bypass Kit Installation The following retail components not included are recommended for the hydraulic connections Cut off valves upstream and downstream from th...

Страница 10: ...rrangement Typical in ground pool arrangement Pool Filter Pump Chemical Treatment Heat Pump Power Cable Inlet Condensation Draining Pipe Water to Pool Water Pump Filter Check Valve Chemical Treatment...

Страница 11: ...a qualified electrician to inspect the electrical outlet socket Initial Operation Make sure the pool is filled with water to the correct level the skimmer and suction fittings are below the water lev...

Страница 12: ...If the pool water level is higher than 1m above or below the heat pump s automatic flow switch adjustment knob your specialist technician may need to adjust the initial startup water flow rate Refrige...

Страница 13: ...to 40 C TIME Setting Press set then press to enter into TIME display Hour setting Press set again to enter into HOUR setting HH flashed then press the or button to adjust the HOUR from 0 to 23 Minute...

Страница 14: ...m the main electrical outlet Or turn off the electrical power at the main circuit breaker panel 2 Shut off the water supply bypass kit to the heat pump 3 Disconnect the IN and OUT water connections an...

Страница 15: ...l every 2 3 days Verify pH level once a week Verify Alkalinity level every 3 4 weeks More often if you own an Automatic Chlorine or Bromine Feeder Verify Calcium Hardness once a month Above tests can...

Страница 16: ...essure lower Compressor failure Probable accumulation of condensation Possible water leak from the water exchanger or from hydraulic unit connection devices Follow the instructions in Initial Operatio...

Страница 17: ...Entering water temperature calibration 9 9 9 9 0 Adjustable Recover to Factory default setting Long press and set simultaneously for 10 seconds to recover to factory default setting it will display 0...

Страница 18: ...nsor Terminal block for T5 connection on PCB broken replace PCB High pressure protection Check bypass valves setting Check system water flow is according to Product Specification section Check high pr...

Страница 19: ...lose step by step the valve 2 to increase water flow and stop when the code disappear Optimal operation of the heat pump occurs when the cooling gas pressure is 22 2 bar This pressure can be read on t...

Страница 20: ...ecessary competence in emission prevention recovery of fluorinated greenhouse gases and safe handling of the relevant type and size of equipment covered by the certificate Record keeping Operators of...

Страница 21: ...7IO HEAT PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 12 15 2016 English 307 IO SAVE THESE INSTRUCTIONS English Page 21 SERVICE BY QUALIFIED TECHNICIANS continued Parts Diagram for qualified technician use on...

Страница 22: ...ON PIPE SETS 10 FAN MOTOR STAND 35 WATER INLET RUBBER RING BLUE 11 ELECTRIC BOX COVER 36 RIGHT SIDE PANEL 12 FAN MOTOR 37 ELECTRIC CABLE CONNECT 13 FAN BLADE 38 PIPE EXCHANGER TO CAPILLARY 14 LOGO 39...

Страница 23: ...y of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you Other than this war...

Отзывы: