background image

(307IO)  HEAT PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  12/15/2016

English

307

IO

SAVE THESE INSTRUCTIONS

English

Page 23

PARTS LIST

Your Heat Pump has been manufactured using the highest quality materials and workmanship. 

All Intex products have been inspected and found free of defects prior to leaving the factory. This 

limited warranty applies only to the Heat Pump and accessories listed below.

This limited warranty is in addition to, and not a substitute for, your legal rights and remedies. To 

the extent that this warranty is inconsistent with any of your legal rights, they take priority. For 

example, consumer laws across the European Union provide statutory warranty rights in 

addition to the coverage you receive from this limited warranty: for information on EU-wide 

consumer laws, please visit the European Consumer Center website at http://ec.europa.eu/

consumers/ecc/contact_en/htm.

The provisions of this limited warranty apply only to the original purchaser and is not 

transferable. This limited warranty is valid for the period noted below from the date of the initial 

retail purchase. Keep your original sales receipt with this document, as proof of purchase will be 

required and must accompany warranty claims or the limited warranty will be invalid.  

   

Heat Pump Warranty – 2 Years

If you find a manufacturing defect in the Heat Pump during the warranty periods noted above, 

please contact the appropriate Intex Service Center listed in the separate “Authorized Service 

Centers” sheet. If the item is returned as directed by the Intex Service Center, the Service Center 

will inspect the item and determine the validity of the claim. If the item is covered by the 

provisions of the warranty, the item will be repaired or replaced, with the same or comparable 

item (at Intex’s choice) at no charge to you.

Other than this warranty, and other legal rights in your country, no further warranties are implied. 

To the extent possibly in your country, in no event shall Intex be liable to you or any third party 

for direct or consequential damages arising out of the use of your Heat Pump, or Intex or its 

agents’ and employees’ actions (including the manufacture of the product). If your country does 

not allow the exclusion or limitation of incidental or consequential damages, this limitation or 

exclusion does not apply to you. 

You should note that this limited warranty does not apply in the following circumstances:

•  If the Heat Pump is subject to negligence, abnormal use or application, accident, improper 

  operation, improper voltage or current contrary to operating instructions, improper 

  maintenance or storage;

•  If the Heat Pump is subject to damage by circumstances beyond Intex’s control, including but 

  not limited to, ordinary wear and tear and damage caused by exposure to fire, flood, freezing, 

  rain, or other external environmental forces;

•  To parts and components not sold by Intex; and/or

•  To unauthorized alterations, repairs or disassembly to the Heat Pump by anyone other than 

  Intex Service Center personnel.

The costs associated with the loss of pool water, chemicals or water damage are not covered by 

this warranty. Injury or damage to any property or person is not covered by this warranty.

Read the owner’s manual carefully and follow all instructions regarding proper operation and 

maintenance of your Heat Pump. Always inspect your product prior to use. This limited warranty 

will be void if use instructions are not followed.

LIMITED WARRANTY

Содержание HP6220

Страница 1: ...ntex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used...

Страница 2: ...TIONS English Page 2 Warnings 3 4 Parts Reference 5 6 Product Specifications 7 Set Up Instructions 8 12 Display Control Panel Operation 13 Maintenance 14 Pool Water Chemistry 14 Heat Pump Caring 15 Tr...

Страница 3: ...embly by adults only Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Position this product away from pool to prevent a child from climbing on produc...

Страница 4: ...supervision or instruction concerning use of the heat pump by a person responsible for their safety The heat pump doesn t work at air temperatures below 8 C Disconnect the power cable from the electr...

Страница 5: ...ote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 L SHAPE O RING 6 11228 2 HEAT PUMP FITTING NUT 2 12567 3 38MM HOSE ADAPTOR 6 12571 4 HEAT PUMP 50MM PIPE ADAPTOR 2 12555 5...

Страница 6: ...e parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 15...

Страница 7: ...e drop 14 kPa Operating water temperature range 15 C 35 C Operating air temperature range 8 C 40 C Class of protection I Type of protection IPX4 Heat exchanger Titanium inside a PVC reservoir Compress...

Страница 8: ...tion containers The heat pump must be fixed and installed on a flat solid vibration free and level support cement slab or prefabricated platform Do not install the heat pump on unstable ground To redu...

Страница 9: ...le discharge area Water Connection and Bypass Kit Installation The following retail components not included are recommended for the hydraulic connections Cut off valves upstream and downstream from th...

Страница 10: ...rrangement Typical in ground pool arrangement Pool Filter Pump Chemical Treatment Heat Pump Power Cable Inlet Condensation Draining Pipe Water to Pool Water Pump Filter Check Valve Chemical Treatment...

Страница 11: ...a qualified electrician to inspect the electrical outlet socket Initial Operation Make sure the pool is filled with water to the correct level the skimmer and suction fittings are below the water lev...

Страница 12: ...If the pool water level is higher than 1m above or below the heat pump s automatic flow switch adjustment knob your specialist technician may need to adjust the initial startup water flow rate Refrige...

Страница 13: ...to 40 C TIME Setting Press set then press to enter into TIME display Hour setting Press set again to enter into HOUR setting HH flashed then press the or button to adjust the HOUR from 0 to 23 Minute...

Страница 14: ...m the main electrical outlet Or turn off the electrical power at the main circuit breaker panel 2 Shut off the water supply bypass kit to the heat pump 3 Disconnect the IN and OUT water connections an...

Страница 15: ...l every 2 3 days Verify pH level once a week Verify Alkalinity level every 3 4 weeks More often if you own an Automatic Chlorine or Bromine Feeder Verify Calcium Hardness once a month Above tests can...

Страница 16: ...essure lower Compressor failure Probable accumulation of condensation Possible water leak from the water exchanger or from hydraulic unit connection devices Follow the instructions in Initial Operatio...

Страница 17: ...Entering water temperature calibration 9 9 9 9 0 Adjustable Recover to Factory default setting Long press and set simultaneously for 10 seconds to recover to factory default setting it will display 0...

Страница 18: ...nsor Terminal block for T5 connection on PCB broken replace PCB High pressure protection Check bypass valves setting Check system water flow is according to Product Specification section Check high pr...

Страница 19: ...lose step by step the valve 2 to increase water flow and stop when the code disappear Optimal operation of the heat pump occurs when the cooling gas pressure is 22 2 bar This pressure can be read on t...

Страница 20: ...ecessary competence in emission prevention recovery of fluorinated greenhouse gases and safe handling of the relevant type and size of equipment covered by the certificate Record keeping Operators of...

Страница 21: ...7IO HEAT PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 12 15 2016 English 307 IO SAVE THESE INSTRUCTIONS English Page 21 SERVICE BY QUALIFIED TECHNICIANS continued Parts Diagram for qualified technician use on...

Страница 22: ...ON PIPE SETS 10 FAN MOTOR STAND 35 WATER INLET RUBBER RING BLUE 11 ELECTRIC BOX COVER 36 RIGHT SIDE PANEL 12 FAN MOTOR 37 ELECTRIC CABLE CONNECT 13 FAN BLADE 38 PIPE EXCHANGER TO CAPILLARY 14 LOGO 39...

Страница 23: ...y of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you Other than this war...

Отзывы: