•  Check if the voltage indicated on the heat pump corresponds to the local 

  mains voltage before you connect the unit.

•  Do not use the heat pump in combination with other heating system such as 

  electric or gas heaters.

•  If the heat pump is damaged during transportation, it must be replaced, please 

  contact your service center or similarly qualified persons in order to avoid a 

 hazard.

•  Always make sure the water connections of the heat pump are properly locked 

  before you start using the machine.

•  Never insert objects directly into the fan, as this will damage the heat pump 

  and void the warranty.

•  Make sure the evaporator fins are not damaged.

•  This appliance is not intended for use by persons with reduced physical, 

  sensory or mental capabilities, or lack of experience and knowledge, unless

  they have been given supervision or instruction concerning use of the heat 

  pump by a person responsible for their safety.

•  The heat pump doesn’t work at air temperatures below 8°C.

•  Disconnect the power cable from the electrical socket when the product will 

  not be used for an extended period of time.

•  Allowing water to freeze inside the unit will damage the heat pump and void 

  the warranty. Drain the water inside the heat pump during winter time or when 

  the ambient temperature drops below 0°C.

•  Installation and maintenance must be performed by qualified technician.

•  Initial system commissioning and decommissioning must only be performed by 

  specialized technician.

•  This product is intended to be used only for the purposes described in the 

 manual!

FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY 

DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS 

INJURY OR DEATH.

These product warnings, instructions and safety rules provided with the product 

represent some common risks of water recreation devices and do not cover all 

instances of risk and danger. Please use common sense and good judgment 

when enjoying any water activity.

WARNING

Содержание HP6220

Страница 1: ...ntex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used...

Страница 2: ...TIONS English Page 2 Warnings 3 4 Parts Reference 5 6 Product Specifications 7 Set Up Instructions 8 12 Display Control Panel Operation 13 Maintenance 14 Pool Water Chemistry 14 Heat Pump Caring 15 Tr...

Страница 3: ...embly by adults only Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Position this product away from pool to prevent a child from climbing on produc...

Страница 4: ...supervision or instruction concerning use of the heat pump by a person responsible for their safety The heat pump doesn t work at air temperatures below 8 C Disconnect the power cable from the electr...

Страница 5: ...ote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 L SHAPE O RING 6 11228 2 HEAT PUMP FITTING NUT 2 12567 3 38MM HOSE ADAPTOR 6 12571 4 HEAT PUMP 50MM PIPE ADAPTOR 2 12555 5...

Страница 6: ...e parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 15...

Страница 7: ...e drop 14 kPa Operating water temperature range 15 C 35 C Operating air temperature range 8 C 40 C Class of protection I Type of protection IPX4 Heat exchanger Titanium inside a PVC reservoir Compress...

Страница 8: ...tion containers The heat pump must be fixed and installed on a flat solid vibration free and level support cement slab or prefabricated platform Do not install the heat pump on unstable ground To redu...

Страница 9: ...le discharge area Water Connection and Bypass Kit Installation The following retail components not included are recommended for the hydraulic connections Cut off valves upstream and downstream from th...

Страница 10: ...rrangement Typical in ground pool arrangement Pool Filter Pump Chemical Treatment Heat Pump Power Cable Inlet Condensation Draining Pipe Water to Pool Water Pump Filter Check Valve Chemical Treatment...

Страница 11: ...a qualified electrician to inspect the electrical outlet socket Initial Operation Make sure the pool is filled with water to the correct level the skimmer and suction fittings are below the water lev...

Страница 12: ...If the pool water level is higher than 1m above or below the heat pump s automatic flow switch adjustment knob your specialist technician may need to adjust the initial startup water flow rate Refrige...

Страница 13: ...to 40 C TIME Setting Press set then press to enter into TIME display Hour setting Press set again to enter into HOUR setting HH flashed then press the or button to adjust the HOUR from 0 to 23 Minute...

Страница 14: ...m the main electrical outlet Or turn off the electrical power at the main circuit breaker panel 2 Shut off the water supply bypass kit to the heat pump 3 Disconnect the IN and OUT water connections an...

Страница 15: ...l every 2 3 days Verify pH level once a week Verify Alkalinity level every 3 4 weeks More often if you own an Automatic Chlorine or Bromine Feeder Verify Calcium Hardness once a month Above tests can...

Страница 16: ...essure lower Compressor failure Probable accumulation of condensation Possible water leak from the water exchanger or from hydraulic unit connection devices Follow the instructions in Initial Operatio...

Страница 17: ...Entering water temperature calibration 9 9 9 9 0 Adjustable Recover to Factory default setting Long press and set simultaneously for 10 seconds to recover to factory default setting it will display 0...

Страница 18: ...nsor Terminal block for T5 connection on PCB broken replace PCB High pressure protection Check bypass valves setting Check system water flow is according to Product Specification section Check high pr...

Страница 19: ...lose step by step the valve 2 to increase water flow and stop when the code disappear Optimal operation of the heat pump occurs when the cooling gas pressure is 22 2 bar This pressure can be read on t...

Страница 20: ...ecessary competence in emission prevention recovery of fluorinated greenhouse gases and safe handling of the relevant type and size of equipment covered by the certificate Record keeping Operators of...

Страница 21: ...7IO HEAT PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 12 15 2016 English 307 IO SAVE THESE INSTRUCTIONS English Page 21 SERVICE BY QUALIFIED TECHNICIANS continued Parts Diagram for qualified technician use on...

Страница 22: ...ON PIPE SETS 10 FAN MOTOR STAND 35 WATER INLET RUBBER RING BLUE 11 ELECTRIC BOX COVER 36 RIGHT SIDE PANEL 12 FAN MOTOR 37 ELECTRIC CABLE CONNECT 13 FAN BLADE 38 PIPE EXCHANGER TO CAPILLARY 14 LOGO 39...

Страница 23: ...y of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you Other than this war...