Spirotest 100 Model 2016 

 

18 

Troubleshooting 

Should a not allowed leak occur, generate a positive pressure inside the mask. Locate the 
leak by using leak detection spray. 
Tip: The test head can be fully disconnected in order to easily locate any leakage by putting 
the test head under water. 

Troubleshooting 

Should a not allowed leak occur, test the mask and the breathing valve separately to locate 
the leak by using tests “5.3 Leak test of S breathing valve” and “5.4 Opening pressure of 
exhalation valve in S mask”. 

 

5.3 Leak test of S breathing valve 

1.  Connect the breathing valve to the Test connection (3) with Adapter hose ST-P49 (G) 

and Adapter breathing valve #1 (M). 

2.  For First breath version: Manually activate (ON) the positive pressure lever on the 

breathing valve.  

3.  Put Rubber plug (J) in the breathing valve’s hose connection (inlet). 

4.  Create a negative pressure of -10 mbar on the Low pressure gauge (2) by pressing 

the Vacuum pump button (10) and the Negative pressure button (14) at the same 
time.  

5.  Start the stop watch and after 15 seconds record the value on the Low pressure 

gauge (2) and compare with the required test value.  

6.  Remove the Rubber plug (J) from the breathing valve. 

7.  Disconnect Adapter hose ST-P49 (G) and Adapter breathing valve #1 (M) from the 

Test connection (3). 

 

Troubleshooting 

The test must be conducted with a dry exhalation valve (in breathing valve). 

 

5.4 Opening pressure of exhalation valve in S mask 

1.  Connect Test adapter BV P/Divator (I) and Adapter for breathing resistance (L) to the 

Test connection (3). 

2.  Remove the breathing valve from mask, if fitted. 

3.  Connect the Adapter for breathing resistance (L) to the mask. 

4.  Create a positive pressure in the mask by pressing the Vacuum pump button (10) and 

the Exhalation button (15).  

5.  Read the opening pressure of exhalation valve on the Low pressure gauge (2) and 

record it in the test protocol. 

6.  Disconnect Test adapter BV P/Divator (I) with Adapter for breathing resistance (L) 

from the mask and from the Test connection (3). 

 

Содержание Spirotest 100

Страница 1: ...ENGLISH Spirotest 100 Model 2016 User manual 32749D01...

Страница 2: ...cted by copyright All rights are reserved Interspiro and Divator are registered trademarks belonging to Interspiro This publication may not be copied photocopied reproduced translated or converted to...

Страница 3: ...eathing valve 15 4 5 Opening pressure of exhalation valve in Spiromatic breathing valve 15 4 6 Static pressure of Spiromatic breathing valve 15 4 7 Automatic activation of positive pressure for Spirom...

Страница 4: ...Spirotest 100 Model 2016 4...

Страница 5: ...st 100 Model 2016 respectively of its components with these operating instructions as well as with the purposes of use mentioned therein or as confirmed by letter In any case Interspiro recommends hav...

Страница 6: ...r the operation of the Spirotest 100 Model 2016 further test accessories are required depending on the equipment to be tested It is absolutely crucial to read the following instructions carefully and...

Страница 7: ...tion button 3 Test connection 12 Test head deflation button 4 Test head 13 Positive pressure button 5 Relief valve 14 Negative pressure button 6 High pressure connection 15 Exhalation button 7 Selecto...

Страница 8: ...6 290 704 I Test adapter BV P Divator 336 290 706 J Rubber plug 97 381 01 K Test adapter MPE P2 336 290 659 L Adapter for breathing resistance S mask 98 597 01 M Adapter breathing valve 1 98 595 01 N...

Страница 9: ...sure gauge 2 7 Disconnect Sealing cap RD 40 A from the Test connection 3 8 Adjust the Low pressure gauge 2 to zero if necessary 9 Low pressure test complete 2 2 High pressure leakage test 1 Connect HP...

Страница 10: ...pen the Relief valve 5 until the test value is reached on the High pressure gauge 1 b Compare the value on the High pressure gauge 1 to the value shown on the pressure gauge of the SCBA set c Record t...

Страница 11: ...the Medium pressure gauge 9 shows 7 5 bar 0 5 bar d Check the dynamic medium pressure by repeating step 3 above NOTE When adjusting it is important always to go from a higher pressure 9 bar to a lower...

Страница 12: ...otocol 3 Push Release button 17 to release remaining pressure 4 Disconnect the Adapter hose ST C95 E from the Medium pressure connection 18 5 Disconnect the HP adapter from the High pressure connectio...

Страница 13: ...of approximately 100 bar is reached on the High pressure gauge 1 then close the cylinder valve 6 Slowly open the Relief valve 5 7 When air is audibly relieved from the breathing valve record the value...

Страница 14: ...approved test value 8 Disconnect the Adapter hose ST P49 G from the Test connection 3 9 Disconnect the breathing valve from the Adapter hose ST P49 G Troubleshooting Should a not allowed leak occur t...

Страница 15: ...SCBA set cylinder valve and manifold 2 Connect the hose from HP adapter to the High pressure connection 6 3 Connect the medium pressure hose from SCBA set to the breathing valve on the Test connection...

Страница 16: ...e Test connection 3 4 8 Air supply capacity for Spiromatic breathing valve 1 Connect Test adapter MPE P2 K to the Test connection 3 2 Connect the black tube of the Test adapter MPE P2 K to the inhalat...

Страница 17: ...he Low pressure gauge 2 by pressing the Vacuum pump button 10 and the Negative pressure button 14 at the same time 7 Start the stop watch and after 15 seconds record the value on the Low pressure gaug...

Страница 18: ...sure gauge 2 by pressing the Vacuum pump button 10 and the Negative pressure button 14 at the same time 5 Start the stop watch and after 15 seconds record the value on the Low pressure gauge 2 and com...

Страница 19: ...p watch and after 15 seconds record the value on the Low pressure gauge 2 in the test protocol and compare with the approved test value 7 Close the cylinder valve 8 Release the remaining pressure 9 Di...

Страница 20: ...positive pressure lever on the breathing valve 5 Slowly open the cylinder valve 6 Release the pressure slightly by pressing the Positive pressure button 13 for 2 seconds 7 Start the stop watch and aft...

Страница 21: ...ing valve 5 Slowly open the cylinder valve 6 Hold the Test adapter MPE P2 K in your hand and carefully manually activate ON the positive pressure lever on the breathing valve 7 Record the value on the...

Страница 22: ...1 to stabilize 5 Close the cylinder valve and record the value on the High pressure gauge 1 6 Start the stop watch and after 1 minute check the value on the High pressure gauge 1 for any decrease in p...

Страница 23: ...Spirotest 100 Model 2016 23 7 Technical Data Width 400 mm Depth 380 mm Height 340 mm Weight 16 5 kg excl test adapters and accessories Mains supply 110 220 V AC 50 60 Hz...

Страница 24: ......

Отзывы: