background image

Spirotest 100 Model 2016 

 

17 

5. Test of S mask and breathing valve 

 

NOTE: A tested and approved regulator is required for all mask and breathing valve tests. 

 

5.1 Leak test of S mask with breathing valve 

1.  Inflate the Test head (4) slightly by pressing the Vacuum pump button (10) and the 

Test head inflation button (11). 

2.  Put mask with breathing valve on to the Test head (4) and firmly tighten the lower 

straps and head strap (top). Do not tighten the upper straps.  

3.  Inflate the test head by pressing the Vacuum pump button (10) and the Test head 

inflation button (11) until the sealing edge of the mask seals tightly around the test 
head. 

4.  Connect the breathing valve (on mask) to the Test connection (3) with Adapter hose 

ST-P49 (G).  

5.  Manually activate (ON) the positive pressure lever on the breathing valve (First 

Breath version), or close the hatch on the mask (Hatch version).  

6.  Create a negative pressure of -10 mbar on the Low pressure gauge (2) by pressing 

the Vacuum pump button (10) and the Negative pressure button (14) at the same 
time.  

7.  Start the stop watch and after 15 seconds record the value on the Low pressure 

gauge (2) and compare with the required test value.  

8.  Disconnect the Adapter hose ST-P49 (G) from the Test connection (3). 

 

Troubleshooting 

If the test values indicate that the mask/breathing valve assembly has a leak then the mask 
and breathing valve should be tested separately as shown in the next procedures. 

 

5.2 Leak test of S mask without breathing valve 

1.  Connect the mask (without breathing valve) to the Test connection (3) with Test 

adapter BV P/Divator (I) and Adapter for breathing resistance (L). 

2.  Create a negative pressure of -10 mbar on the Low pressure gauge (2) by pressing 

the Vacuum pump button (10) and the Negative pressure button (14) at the same 
time. 

3.  Start the stop watch and after 1 minute record the value on the Low pressure gauge 

(2) and compare with the required test value. 

4.  Disconnect Test adapter BV P/Divator (I) with Adapter for breathing resistance (L) 

and the mask from the Test connection (3). 

 

Содержание Spirotest 100

Страница 1: ...ENGLISH Spirotest 100 Model 2016 User manual 32749D01...

Страница 2: ...cted by copyright All rights are reserved Interspiro and Divator are registered trademarks belonging to Interspiro This publication may not be copied photocopied reproduced translated or converted to...

Страница 3: ...eathing valve 15 4 5 Opening pressure of exhalation valve in Spiromatic breathing valve 15 4 6 Static pressure of Spiromatic breathing valve 15 4 7 Automatic activation of positive pressure for Spirom...

Страница 4: ...Spirotest 100 Model 2016 4...

Страница 5: ...st 100 Model 2016 respectively of its components with these operating instructions as well as with the purposes of use mentioned therein or as confirmed by letter In any case Interspiro recommends hav...

Страница 6: ...r the operation of the Spirotest 100 Model 2016 further test accessories are required depending on the equipment to be tested It is absolutely crucial to read the following instructions carefully and...

Страница 7: ...tion button 3 Test connection 12 Test head deflation button 4 Test head 13 Positive pressure button 5 Relief valve 14 Negative pressure button 6 High pressure connection 15 Exhalation button 7 Selecto...

Страница 8: ...6 290 704 I Test adapter BV P Divator 336 290 706 J Rubber plug 97 381 01 K Test adapter MPE P2 336 290 659 L Adapter for breathing resistance S mask 98 597 01 M Adapter breathing valve 1 98 595 01 N...

Страница 9: ...sure gauge 2 7 Disconnect Sealing cap RD 40 A from the Test connection 3 8 Adjust the Low pressure gauge 2 to zero if necessary 9 Low pressure test complete 2 2 High pressure leakage test 1 Connect HP...

Страница 10: ...pen the Relief valve 5 until the test value is reached on the High pressure gauge 1 b Compare the value on the High pressure gauge 1 to the value shown on the pressure gauge of the SCBA set c Record t...

Страница 11: ...the Medium pressure gauge 9 shows 7 5 bar 0 5 bar d Check the dynamic medium pressure by repeating step 3 above NOTE When adjusting it is important always to go from a higher pressure 9 bar to a lower...

Страница 12: ...otocol 3 Push Release button 17 to release remaining pressure 4 Disconnect the Adapter hose ST C95 E from the Medium pressure connection 18 5 Disconnect the HP adapter from the High pressure connectio...

Страница 13: ...of approximately 100 bar is reached on the High pressure gauge 1 then close the cylinder valve 6 Slowly open the Relief valve 5 7 When air is audibly relieved from the breathing valve record the value...

Страница 14: ...approved test value 8 Disconnect the Adapter hose ST P49 G from the Test connection 3 9 Disconnect the breathing valve from the Adapter hose ST P49 G Troubleshooting Should a not allowed leak occur t...

Страница 15: ...SCBA set cylinder valve and manifold 2 Connect the hose from HP adapter to the High pressure connection 6 3 Connect the medium pressure hose from SCBA set to the breathing valve on the Test connection...

Страница 16: ...e Test connection 3 4 8 Air supply capacity for Spiromatic breathing valve 1 Connect Test adapter MPE P2 K to the Test connection 3 2 Connect the black tube of the Test adapter MPE P2 K to the inhalat...

Страница 17: ...he Low pressure gauge 2 by pressing the Vacuum pump button 10 and the Negative pressure button 14 at the same time 7 Start the stop watch and after 15 seconds record the value on the Low pressure gaug...

Страница 18: ...sure gauge 2 by pressing the Vacuum pump button 10 and the Negative pressure button 14 at the same time 5 Start the stop watch and after 15 seconds record the value on the Low pressure gauge 2 and com...

Страница 19: ...p watch and after 15 seconds record the value on the Low pressure gauge 2 in the test protocol and compare with the approved test value 7 Close the cylinder valve 8 Release the remaining pressure 9 Di...

Страница 20: ...positive pressure lever on the breathing valve 5 Slowly open the cylinder valve 6 Release the pressure slightly by pressing the Positive pressure button 13 for 2 seconds 7 Start the stop watch and aft...

Страница 21: ...ing valve 5 Slowly open the cylinder valve 6 Hold the Test adapter MPE P2 K in your hand and carefully manually activate ON the positive pressure lever on the breathing valve 7 Record the value on the...

Страница 22: ...1 to stabilize 5 Close the cylinder valve and record the value on the High pressure gauge 1 6 Start the stop watch and after 1 minute check the value on the High pressure gauge 1 for any decrease in p...

Страница 23: ...Spirotest 100 Model 2016 23 7 Technical Data Width 400 mm Depth 380 mm Height 340 mm Weight 16 5 kg excl test adapters and accessories Mains supply 110 220 V AC 50 60 Hz...

Страница 24: ......

Отзывы: