Spirotest 100 Model 2016
10
3. Test of regulator
3.1 Pressure gauge accuracy
1. Connect HP Adapter 300 bar (B) or HP Adapter 200 bar (C) between SCBA set
cylinder valve and manifold.
2. Connect the hose from the HP adapter to the High pressure connection (6).
3. Connect the medium pressure hose from the SCBA set to the breathing valve. Make
sure the breathing valve is in OFF position.
4. Slowly open the cylinder valve.
5. When the pressure stabilizes close the cylinder valve.
6. Monitor the High pressure gauge (1) and compare that value to the value shown on
the pressure gauge of the SCBA set.
7. For each of the test values listed in the test protocol, do the following:
a. Slowly open the Relief valve (5) until the test value is reached on the High
pressure gauge (1).
b. Compare the value on the High pressure gauge (1) to the value shown on the
pressure gauge of the SCBA set.
c. Record the result in the test protocol.
NOTE: If a pressure gauge fails this test – it must be replaced.
3.2 Activating pressure of warning whistle
1. Slowly open the Relief valve (5).
2. Record the value shown on the High pressure gauge (1) when the whistle starts to
sound.
3. Leave the Relief valve (5) open until the remaining pressure is vented.
4. Close the Relief valve (5).
5. Disconnect the breathing valve from the medium pressure hose.
Troubleshooting
If the activating pressure is not according to the value in the test protocol, the warning whistle
is defective and must be repaired by Interspiro or by a holder of a valid Interspiro Service
Certificate for the equipment in question.