Spirotest 100 Model 2016
12
3.5 High pressure leakage test
1. Close the cylinder valve.
2. Observe the High pressure gauge (1) for 1 minute and record the leakage value in
the test protocol.
3. Push Release button (17) to release remaining pressure.
4. Disconnect the Adapter hose ST-C95 (E) from the Medium pressure connection (18).
5. Disconnect the HP adapter from the High pressure connection (6).
If a complete SCBA set is to be tested – go to the relevant section depending on mask
type: “4. Test of Spiromatic mask and breathing valve” or “5. Test of S mask and breathing
valve”.