OPERATION:
Touchless Configuration Unit Assembly with Battery
This section covers the replacement instructions for touchless configuration unit assembly with battery. The purpose of the
touchless configuration option is to allow customer to pre-configure the printer without taken the printer out of the box. The
touchless configuration unit contain a battery powered RFID chip that store the configuration information.
To configure the touchless configuration, an RFID reader is required. For example, an IF2 with standard RFID antenna or an
IP30 connecting to handheld computer.
When replacing the touchless configuration unit, the unit has to be re-programmed with an RFID reader to match the printer
configuration information.
Tools Required
Description
Part Number
Torx Driver
T8
Parts Required
Item Part Number
Description
Qty
1
705-625S-001
Touchless, Config Unit, Assembly, Spare, PM43 (include screws and lithium
battery 317-235-001)
1
2
800-593-006
Screw, Plastite, M3x6, PH, Torx, T10 (3 lbf.in/3.5kgf.cm)
2
Touchless Assembly Replacement
1. Remove the front panel to access the touchless configuration unit for replacement. See page 11 on how to remove the
front panel.
2. Remove the torx screws securing the touchless configuration unit PCBA to the front panel. See Figure 1.
3. Disconnect the touchless configuration unit cable from connector P20 on the main logic board (MLB) and ground cable to
remove the touchless configuration unit assembly
4. Reverse the procedure for re-installation.
Figure 1
Touchless Config Unit Assembly
2