100
ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Chapter —Commands
SA – Setup Adjust
Description
This command is used to control the activation and storage of
setup commands / values.
Syntax
SAp
1
Parameters
p
1
Setup Adjust value:
0 All setup commands remain active and values are saved when
changed. The printer will use stored setup values (Default).
1 All setup parameters are locked and commands will be ignored. The
printer will use previously stored setup values.
2 All setup commands within forms will be ignored.
Remarks
The
SA
command affects the following setup commands:
R
,
r
,
D
,
j
,
J
,
q
,
Q
,
S
,
Z
, and
SPC
. The current
SA
value is stored in
Flash memory and printed on the test label.
Example
SA2
↵
:All of the commands listed above that are called
within forms will be ignored.
Содержание EasyCoder PD4
Страница 1: ...Programmer s Reference Manual ESim v5 12 for EasyCoder PD4 Bar Code Label Printer ...
Страница 22: ...16 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 3 Setting Up the Printer ...
Страница 134: ...128 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 7 Commands ...
Страница 138: ...132 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 8 Fonts ...
Страница 154: ...148 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 9 Code Pages and Character Sets ...