ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
12
Chapter —Commands
Example
Serial
command
Manual
action
Reply on RS232
Comments
US
↵
<ACK>
Enable Error Reporting
AA
↵
(Nothing happens)
Command with syntax error
(#01)
Lift the
printhead
<NAK>11<XOFF>
Manual action to generate error
(#11) and wait in position of
error-waiting-recovering.
UV
↵
(Nothing happens)
Command to print product ID
will be queued
^ee
↵
01,11<CR><LF>
Command reports direct all
errors/status
Close the
printhaed
<XON>1-972660-00,
→
→
PD4 5.12<CR><LF>
Manual action to release error
#11. Command UV will now
be performed.
P
↵
<NAK>01<XOFF>
Command to print, reports
syntax error (#01)
Press
FEED key
<XON>
Manual action to release error
status