ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
21
Chapter 5—Editing in Form Edit Mode
Name the Form
Name of this form is TEST.
Command
Explanation
↵
CR/LF to start command structure
FK"TEST"
↵
Delete any existing form named TEST
FS"TEST"
↵
Start store form named TEST
Define Variables
The first variable (V00) has a maximum size of 15 characters.
The second variable (V01) has 10 characters and prints in reverse.
The third variable (V02) has a maximum size of 8 characters.
Command
Explanation
V00,15,N,"Enter Product name:"
↵
Define first variable
V01,10,L,"Enter Model number:"
↵
Define second variable
V02,8,N,"Checked by:"
↵
Define third variable
The text within quotes are prompts, which will be sent from the printer
to the host when the label form is retrieved (serial communication only).
Define a Counter
The counter has maximum 6 digits.
Command
Explanation
C0,6,L,+1,"Enter Serial Number:"
↵
Define counter
Note:
The variables (V00, V01, V02) and counter (C0), are
defined within this label form named TEST. The next label
form containing variables and counters, will again start with
V00 and C0. If variable data is being sent from an external data
base, omit the text between the quotes and replace with a space
character, for example
V00,15,N," "
.
Содержание EasyCoder PD4
Страница 1: ...Programmer s Reference Manual ESim v5 12 for EasyCoder PD4 Bar Code Label Printer ...
Страница 22: ...16 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 3 Setting Up the Printer ...
Страница 134: ...128 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 7 Commands ...
Страница 138: ...132 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 8 Fonts ...
Страница 154: ...148 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 9 Code Pages and Character Sets ...