11
ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Chapter —Commands
Example
This example shows how the field justification works in variable
fields:
FK"TEST7"
↵
FS"TEST7"
↵
V00,10,L,"Variable 00"
↵
V01,10,R,"Variable 01"
↵
V02,10,C,"Variable 02"
↵
V03,10,N,"Variable 03"
↵
A50,50,0,3,1,1,N,"TEXT"V00":Left justified"
↵
A50,100,0,3,1,1,N,"TEXT"V01":Right justified"
↵
A50,150,0,3,1,1,N,"TEXT"V02":Center justified"
↵
A50,200,0,3,1,1,N,"TEXT"V03":No justification"
↵
FE
↵
Refer to the
?
command for continuation of this example!
Содержание EasyCoder PD4
Страница 1: ...Programmer s Reference Manual ESim v5 12 for EasyCoder PD4 Bar Code Label Printer ...
Страница 22: ...16 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 3 Setting Up the Printer ...
Страница 134: ...128 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 7 Commands ...
Страница 138: ...132 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 8 Fonts ...
Страница 154: ...148 ESim v5 12 for EasyCoder PD4 Programmer s Reference Manual Chapter 9 Code Pages and Character Sets ...