Intermec EasyCoder 501 XP & 601 XP – Service Manual
97
Chapter 10 Label Taken Sensor
• Using the screw included in the kit, fi t the sensor/bracket assem-
bly to the inner wall of the print unit as shown by the two
illustrations below. Fit the cable underneath the top part of the
bracket, as illustrated in the lowermost picture.
• Slip the cable of the label taken sensor through the hole in the
center section of the printer into the electronics compartment.
• Connect the cable to P51 on the CPU board. Be careful so the
cable does not interfere with any moving mechanical parts or
the transfer ribbon.
• Connect the power cord and switch on the power.
WARNING!
The electronics compartment contains high voltage wires and
components. Use a non-conductive screwdriver to avoid the
risk of causing a short-circuit!
10.2 Installation, cont.
Note!
Illustrations show installation on an
EasyCoder 501 XP printer. The same
principles apply to installation on an
EasyCoder 601 XP.