Intermec EasyCoder 501 XP & 601 XP – Service Manual
70
Chapter 8 Print Unit
8.7 Printhead, cont.
(EasyCoder 501 XP and 601 XP), cont.
The printhead is fi tted to a bracket using two screws. The printhead
and the bracket are always delivered as a complete assembly. Two
hooked fi ngers at the rear of the bracket are fi tted over the headlift
shaft so as to hold the printhead in place. Two U-shaped tabs on
either side of the bracket connect to bearings on the platen roller
shaft when the printhead is closed, making sure that the printhead
becomes properly aligned with the platen roller. There are no facil-
ities for adjusting the position of the printhead relative the platen
roller, neither longitudinally nor laterally.
There are two cables from the printhead to the CPU board:
• The outermost cable (protected by a black plastic tube) is used
for the power to the printhead and is connected to X2 on the
Power Supply board.
• The innermost cable (20-p blue fl at cable) is used for data to the
printhead and is connected to P41
(marked “TPH”) on the CPU
board.
Printhead
Bracket
Blue Connector
(to P41 on CPU Board)
White Connector
(to X2 on Power Supply)
“Finger”
“Finger”
Illustration shows the printhead of an EasyCoder 501 XP.
The printhead and bracket of the EasyCoder 601 XP is wider, else
there is no difference.
Содержание EasyCoder 501XP
Страница 1: ...Service Manual EasyCoder 501 XP 601 XP Bar Code Label Printers ...
Страница 113: ...Intermec EasyCoder 501 XP 601 XP Service Manual 111 Chapter 14 Power Supply 14 2 Components cont 1 971601 27 Back Side ...
Страница 208: ...Intermec EasyCoder 501 XP 601 XP Service Manual 206 Notes ...
Страница 209: ......