![Interlogix UltraView PTZ Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/interlogix/ultraview-ptz/ultraview-ptz_installation-manual_2077199055.webp)
45
Figure 35.Attaching the housing safety cable to the arm safety chain
12. Return to
Installing the housing
on page 12 to finish installing the dome.
Opening a conduit hole
Open a conduit hole for a 3/4 in. (19 mm) or 1/2 in. (13 mm) conduit connector, if you need to bring the facility
cables in through the side of the arm.
To open the conduit hole, see
Figure 36
on page 46 and do the following:
1. Locate the dimple on the side of the arm.
2. Drill a 3/8 in. (10 mm) pilot hole through the dimple.
3. Enlarge the pilot hole to 1-7/64 in. (28 mm) for a 3/4 in. conduit connector or to 7/8 in. (22 mm) for a
1/2 in. conduit connector.
4. Return to step 2 of
Installing the wall-mount arm
on page 42.
Quick tie
Safety chain
Clip
Safety cable
Содержание UltraView PTZ
Страница 1: ...UltraView PTZ Installation Manual...
Страница 6: ...UltraView PTZ Installation Manual vi...
Страница 10: ...UltraView PTZ Installation Manual x...
Страница 18: ...UltraView PTZ Installation Manual 8...
Страница 46: ...UltraView PTZ Installation Manual 36...
Страница 60: ...UltraView PTZ Installation Manual 50...