Troubleshooting
This section provides information to help you diagnose and solve various problems that may arise while
configuring or using your Interloix product.
Housing board power indication
When power is received by the housing board through the power connection, the housing power LED 2
appears orange (
Figure 29
). It appears orange because the red and green internal LEDs both illuminate. The
housing board power LED is located on the PC board that is attached to the underside of the upper bracket. It
can be seen before the camera assembly is installed.
Figure 29.Housing board power indication
Common installation issues
Following are the most common troubleshooting issues and their solutions.
• The dome is resetting during power-up, not powering up at all, or powering up but not operating as
expected.
Verify that you are supplying sufficient power for your model of dome. See
Table 2
on page 5.
• Video is not appearing on the monitor screen.
If the dome is not powered or the programming is not running properly, remove and reinstall the camera
assembly. See
Camera assembly, shroud, bubble dome
on page 25.
If the video still does not appear, then check the video cable and verify that it is properly connected. For
UTP video, ensure that the + and - ends of the cable are correctly connected to maintain the polar
sensitivity of the UTP video cable. See
Wiring the housing board
on page 22.
• Either there is video, but no PTZ control, or Protocol flashes on the screen.
First, verify the address of the dome. You can do this easily by pressing and holding the
view
key on the
KTD-405 keypad. If the PTZ is receiving commands from the keypad, the dome’s information will be
displayed on the monitor screen. If the dome’s information is not displayed, or after moving the joystick
around for a while the "Protocol" message starts flashing on the screen, verify the address and/or protocol
using the procedure in
Setting the protocol
on page 27. If you still don’t have control of the PTZ, verify that
the data cable is properly connected. See
Wiring the housing board
on page 22.
Power LED 2
Power LED 1
(see
Table 5
on
page 21)
Содержание UltraView PTZ
Страница 1: ...UltraView PTZ Installation Manual...
Страница 6: ...UltraView PTZ Installation Manual vi...
Страница 10: ...UltraView PTZ Installation Manual x...
Страница 18: ...UltraView PTZ Installation Manual 8...
Страница 46: ...UltraView PTZ Installation Manual 36...
Страница 60: ...UltraView PTZ Installation Manual 50...