NX-148E- RF LCD Touchpad w ith Receiver Installation Instructions
9
Silent exit (EXIT)
To silence the exit beeps during exit delay (while the system is
disarmed), do the following:
1. Enter * EXIT.
2. Enter your user code.
3. To exit, press #.
Reference tables
Table 9. Service menu messages
Message
Explanation
Control over current
A short circuit of a pow er supply has
occurred.
Control siren trouble
Open circuit on the bell or siren circuit.
Control box tamper
(Optional) The box tamper circuit has
activated.
Control phone trouble
The phone line connected to the control is
not operating properly.
Control fail to comm.
The control made an unsuccessful attempt
to communicate a message to the central
station.
Control ground fault
A short to ground has been detected on a
control circuit.
Control loss of time
Your system has lost total pow er and needs
the clock reset.
Control pow er trouble
The main pow er to the system is off.
Control low battery
The standby battery is low .
Expansion aux comm
fail
A auxiliary reporting device (i.e. NX-580E,
NX-582E, etc.) has failed to communicate.
Expansion over
current
A short circuit of an expansion devices
pow er supply has occurred.
Expansion pow er
trouble
The main pow er to an expansion pow er
supply is off.
Expansion low battery An expansion pow er supply has a low
battery.
Expansion box tamper A box containing an expansion device has
been opened.
Expansion RF jammed A radio receiver is being jammed.
Expansion trouble
An expansion device or touchpad is not
reporting to the control panel.
Expansion siren
trouble
An expansion device has detected trouble
on the bell or siren circuit.
Zone tamper, press *
A zone is tampered. Press * to identify the
tampered zone.
Zone low battery,
press *
A w ireless device has a low battery. Press *
to identify the zone.
Zone lost, press *
A w ireless or multiplexed zone device is not
reporting to the control. Press * to identify
the zone.
Zone trouble, press *
A zone is experiencing trouble. Press * to
identify the zone.
Table 10. Log m essages
Display
Description
TXlobat
Transmitter low battery
ZN Lost
Zone lost - A w ireless multiplexed zone
device is not reporting to the control.
Duress
The control has been armed or disarmed
w ith a Duress code.
Man Fire
Manual fire - Touchpad
Fire
has been
activated.
Aux 2
Auxiliary 2 - Touchpad
Medical
has been
activated.
Panic
Touchpad
Panic
has been activated.
KP Tamper
Touchpad Tamper - The touchpad tamper
has been activated.
BoxTamp
Box Tamper - The box tamper circuit has
been activated.
AC Fail
AC failure has been detected.
OverCur
Over current - A short circuit of a pow er
supply has occurred.
Srn Tamp
Siren tamper - A siren or speaker tamper
has been detected.
Tel Flt
Telephone fault - A telephone fault or
tamper has been detected.
Exp Trb
Expansion trouble - An expansion device or
touchpad is not reporting to the control.
Log Full
The event log is full.
Open
Reports, user number, date, time and
partition of opening.
Close
Reports, user number, date, time and
partition of closing.
Exit Err
Exit error - Entry/exit zone w as faulted w hen
the exit delay expired.
Rec Close
Recent close - An alarm occurred w ithin 5
minutes of the control being armed.
Autotest
Automatic test - Sending a communicator
test at a specified interval.
Start Prog
Start programming - Local Programming
has started.
End Prog
End programming -Local programming has
ended.
Start Dnld
Start dow nload - Dow nload session has
started.
End Dnld
End dow nload - Dow nload session has
ended.
Cancel
Cancel w as initiated w ithin 5 minutes of an
alarm.
Gnd Flt
Ground fault - A short to ground has been
detected.