background image

NX-148E- RF LCD Touchpad w ith Receiver Installation Instructions 

Silent exit (EXIT) 

To silence the exit beeps during exit delay (while the system is 

disarmed), do the following: 

1.  Enter * EXIT.   

2.  Enter your user code. 

3.  To exit,  press #. 

Reference tables 

Table 9. Service menu messages 

Message 

Explanation 

Control over current 

A short circuit of a pow er supply has 
occurred. 

Control siren trouble 

Open circuit on the bell or siren circuit. 

Control box tamper 

(Optional) The box tamper circuit has 
activated. 

Control phone trouble 

The phone line connected to the control is 
not operating properly. 

Control fail to comm. 

The control made an unsuccessful attempt 
to communicate a message to the central 
station. 

Control ground fault 

A short to ground has been detected on a 
control circuit. 

Control loss of time 

Your system has lost total pow er and needs 
the clock reset. 

Control pow er trouble 

The main pow er to the system is off. 

Control low  battery 

The standby battery is low . 

Expansion aux comm 
fail 

A auxiliary reporting device (i.e. NX-580E, 
NX-582E, etc.) has failed to communicate. 

Expansion over 
current 

A short circuit of an expansion devices 
pow er supply has occurred. 

Expansion pow er 
trouble 

The main pow er to an expansion pow er 
supply is off. 

Expansion low  battery  An expansion pow er supply has a low  

battery. 

Expansion box tamper  A box containing an expansion device has 

been opened. 

Expansion RF jammed  A radio receiver is being jammed. 

Expansion trouble 

An expansion device or touchpad is not 
reporting to the control panel. 

Expansion siren 
trouble 

An expansion device has detected trouble 
on the bell or siren circuit. 

Zone tamper, press * 

A zone is tampered. Press * to identify the 
tampered zone. 

Zone low  battery, 
press * 

A w ireless device has a low  battery. Press * 
to identify the zone. 

Zone lost, press * 

A w ireless or multiplexed zone device is not 
reporting to the control. Press * to identify 
the zone. 

Zone trouble, press * 

A zone is experiencing trouble. Press * to 
identify the zone. 

Table 10. Log m essages 

Display 

Description 

TXlobat 

Transmitter low  battery  

ZN Lost 

Zone lost - A w ireless multiplexed zone 
device is not reporting to the control. 

Duress 

The control has been armed or disarmed 
w ith a Duress code. 

Man Fire 

Manual fire - Touchpad 

Fire

 has been 

activated. 

Aux 2 

Auxiliary 2 - Touchpad 

Medical 

has been 

activated. 

Panic 

Touchpad 

Panic

 has been activated. 

KP Tamper 

Touchpad Tamper  - The touchpad tamper 
has been activated. 

BoxTamp 

Box Tamper  - The box tamper circuit has 
been activated. 

AC Fail 

AC failure has been detected. 

OverCur 

Over current - A short circuit of a pow er 
supply has occurred. 

Srn Tamp 

Siren tamper - A siren or speaker tamper 
has been detected. 

Tel Flt 

Telephone fault - A telephone fault or 
tamper has been detected. 

Exp Trb 

Expansion trouble - An expansion device or 
touchpad is not reporting to the control. 

Log Full 

The event log is full. 

Open 

Reports, user number, date, time and 
partition of opening. 

Close 

Reports, user number, date, time and 
partition of closing. 

Exit Err 

Exit error - Entry/exit zone w as faulted w hen 
the exit delay expired. 

Rec Close 

Recent close - An alarm occurred w ithin 5 
minutes of the control being armed. 

Autotest 

Automatic test - Sending a communicator 
test at a specified interval. 

Start Prog 

Start programming - Local Programming 
has started. 

End Prog 

End programming  -Local programming has 
ended. 

Start Dnld 

Start dow nload - Dow nload session has 
started. 

End Dnld 

End dow nload - Dow nload session has 
ended. 

Cancel 

Cancel w as initiated w ithin 5 minutes of an 
alarm. 

Gnd Flt 

Ground fault - A short to ground has been 
detected. 

Содержание NX-148E-RF

Страница 1: ...8E NX 8V2 NX 6V2 or NX 4V2 and downloading via modem make sure the control panel version is equal to or greater than the following versions NX 8E 17 00 NX 8V2 1 04 NX 6V2 1 05 NX 4V2 1 04 Make sure yo...

Страница 2: ...18 2000 ft 610 m 16 2500 ft 760 m 16 7 Run the antenna wires through the antenna holes in the mounting plate Figure 2 and into the wall 8 To mountthe touchpad to the mounting plate place the top of t...

Страница 3: ...bank Location 594 The bank setting is based on the zone capabilities ofboth the receiver and the panel and mustbe set before you add learn transmitters 6 Enter 400 to enter the sensor transm itter le...

Страница 4: ...er will be displayed for the keyfob partitions Press the partition number to toggle the partition on and off 6 To continue programming keyfob transmitter partition settings repeatsteps 4 to 8 7 To exi...

Страница 5: ...Note Press repeatedlyto scroll through available functions Table 4 Touchpad functions Function number Function 0 Adjust touchpad tone 1 Temp master mode View zone status 2 Service menu 3 View alarmmem...

Страница 6: ...ss or to turn the selected device on or off 4 Repeatsteps 2 and 3 until all devices have been programmed 5 To exit press Unit and house codes for X10 47 To program the specific X10 unit and house code...

Страница 7: ...the central monitoring station Open 75 9 25 17 57 P3 Table 10 lists some ofthe possible eventlog messages Adjust view brightness ofLCD 91 To adjustthe view and brightness ofthe LCD display do the fol...

Страница 8: ...ge Enables custommessage display 10 Clock Enables clockdisplay 11 Custom message lock Prevents over writing the custom message during touchpad copy 12 Select an option Programs specialcharacteristics...

Страница 9: ...the tampered zone Zone low battery press A w ireless devicehas a low battery Press to identify the zone Zone lost press A w ireless or multiplexed zone device is not reporting to the control Press to...

Страница 10: ...ob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob...

Страница 11: ...Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supe...

Страница 12: ...Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supe...

Страница 13: ...sor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob P...

Страница 14: ...temperature 30 to 140 F 34 to 60 C Humidity 90 relative noncondensing Dimensions 5 x 6 x 1 in 12 7 x 15 2 x 2 5 cm Regulatory information FCC compliance This device complies w ith part 15 of the FCC...

Отзывы: