background image

 

P/N 466-2198 

• REV F • OCT12 

 

 

NX-148E-RF LCD Touchpad  with Receiver 
Installation Instructions 

Content 

Contact  information    1

 

Product  summary   1

 

Installation    2

 

Transmitter  programming    2

 

Touchpad  programming    5

 

Reference  tables    9

 

Specifications    14

 

Regulatory  information    14

 

 

Contact  information 

www.utcfireandsecurity.com

 or 

www.interlogix.com

 

For customer support, see 

www.interlogix.com/customer-

support

  

© 2012  UTC Fire & Security Americas Corporation, Inc.  

Interlogix is part of UTC Climate Controls & Security, a unit of 
United Technologies Corporation.   
All rights reserved.

 

Product  summary 

The NX-148E-RF Touchpad with Receiver combines touchpad 

and receiver capabilities into a single device for use with all 

NetworX control panels except CF (commercial fire) panels. 

Note:

  When using this touchpad with an NX-8E, NX-8V2,  NX-

6V2, or NX-4V2 and downloading via modem, make sure the 

control panel version is equal to or greater than the following 

versions: 

• 

NX-8E   

17.00 

• 

NX-8V2   

1.04 

• 

NX-6V2   

1.05 

• 

NX-4V2   

1.04 

Make sure you are using DL900 version 2.11 or greater 

software. 

Installation  guidelines 

Use the following installation guidelines: 

• 

Mount transmitters as close as possible to the touchpad. 

For best results, we recomm end the distance between the 

transmitter and the touchpad be less than 100 ft. (30.5 m). 

• 

Mount the touchpads in an environmentally controlled area 

with a temperature range from 32 to 120°F (0° to 49°C). 

• 

When mounting the touchpad, allow at least 3 in. (7.6 cm) 

below the touchpad for the swing-down door (

Figure 1

). 

Figure 1. Side view 

 

• 

Use 

Table 1

 to determine the maximum wire lengths 

allowed between the touchpad and the panel. 

Tools and supplies needed 

• 

Pencil 

• 

Phillips screwdriver 

• 

Drill 

• 

15/64 in. drill bit 

• 

Mounting screws (provided) 

• 

Wall anchors (optional) 

• 

4-conductor, 22, 18, 16, 14 or 12-gauge wire (see 

Table 

1

). 

Содержание NX-148E-RF

Страница 1: ...8E NX 8V2 NX 6V2 or NX 4V2 and downloading via modem make sure the control panel version is equal to or greater than the following versions NX 8E 17 00 NX 8V2 1 04 NX 6V2 1 05 NX 4V2 1 04 Make sure yo...

Страница 2: ...18 2000 ft 610 m 16 2500 ft 760 m 16 7 Run the antenna wires through the antenna holes in the mounting plate Figure 2 and into the wall 8 To mountthe touchpad to the mounting plate place the top of t...

Страница 3: ...bank Location 594 The bank setting is based on the zone capabilities ofboth the receiver and the panel and mustbe set before you add learn transmitters 6 Enter 400 to enter the sensor transm itter le...

Страница 4: ...er will be displayed for the keyfob partitions Press the partition number to toggle the partition on and off 6 To continue programming keyfob transmitter partition settings repeatsteps 4 to 8 7 To exi...

Страница 5: ...Note Press repeatedlyto scroll through available functions Table 4 Touchpad functions Function number Function 0 Adjust touchpad tone 1 Temp master mode View zone status 2 Service menu 3 View alarmmem...

Страница 6: ...ss or to turn the selected device on or off 4 Repeatsteps 2 and 3 until all devices have been programmed 5 To exit press Unit and house codes for X10 47 To program the specific X10 unit and house code...

Страница 7: ...the central monitoring station Open 75 9 25 17 57 P3 Table 10 lists some ofthe possible eventlog messages Adjust view brightness ofLCD 91 To adjustthe view and brightness ofthe LCD display do the fol...

Страница 8: ...ge Enables custommessage display 10 Clock Enables clockdisplay 11 Custom message lock Prevents over writing the custom message during touchpad copy 12 Select an option Programs specialcharacteristics...

Страница 9: ...the tampered zone Zone low battery press A w ireless devicehas a low battery Press to identify the zone Zone lost press A w ireless or multiplexed zone device is not reporting to the control Press to...

Страница 10: ...ob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob...

Страница 11: ...Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supe...

Страница 12: ...Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supe...

Страница 13: ...sor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob P...

Страница 14: ...temperature 30 to 140 F 34 to 60 C Humidity 90 relative noncondensing Dimensions 5 x 6 x 1 in 12 7 x 15 2 x 2 5 cm Regulatory information FCC compliance This device complies w ith part 15 of the FCC...

Отзывы: