ENTERING THE PROGRAM MODE

 

To enter the Program Mode, press [

r

]-[

8

].  At this time, the LCD screen will prompt you for the programming code. 

Next, enter the  "Go To Program Code" (FACTORY DEFAULT IS [

9

]-[

7

]-[

1

]-[

3

]).  If the "Go To Program Code" is valid, 

the LCD screen will prompt you for the device address you wish to program.  You are now in the Program Mode and 
ready to select the module to program.  
 
 

SELECTING THE MODULE TO PROGRAM

 

Since all modules connected to the NX8-E are programmed through the keypad, the module you are programming 
should be the first entry.  To program the NX8-E Control Panel, enter [

0

]-[

#

]. The [

0

] is the module number of the 

control and the [

#

] is the entry key. Other module entry numbers can be found in their corresponding manuals. 

 
 

PROGRAMMING A LOCATION

 

Once the number of the module to be programmed has been entered, the LCD screen will prompt you for a location 
number.  Any location can be accessed by directly entering the desired programming location followed by the pound 
[

#

] key.  If the location entered is a valid location, the top line of the LCD screen will display the location number on the 

left and the segment number on the right.  The bottom line of the display will show the current data.  This data will be 
displayed and entered according to the type of data used (numerical, binary, or character data).  Follow the 
instructions below for each type of data. 
 

!

 

 NUMERICAL DATA

: The top line of the display will show the current location number on the left and the segment 

number on the right. The data will be displayed on the bottom line. The hex equivalent will be shown in parenthesis.  
To change the data in the current location enter the number followed by [

r

]. The data will be entered and the segment 

will be incremented by 1. The data for this segment will now be displayed. Continue this process until the last segment 
is programmed.  When the last segment is reached, the keypad will prompt you for the next location.  If you wish to exit 
this location before the last segment is reached, press the [

#

] key.  This keypress will not save the changes made to 

current segment, but will exit the location.  To proceed to the next location, press the [

Police

] key.  To return to the 

previous location, press the [

Fire

] key.  To re-enter the last location, press the [

Auxiliary

] key.  

 

!

  BINARY DATA

: The top line of the display will show the current location number on the left and the segment 

number on the right.  The data will be displayed on the bottom line with the numbers 1-8 in the first 8 characters.  If the 
number appears, this binary switch is on.  If a minus sign (-) appears where the number should be, this switch is off.  
Toggle numbers on or off using the corresponding number digit (1 to toggle 1; 8 to toggle 8).  When the numbers are 
in the desired state, enter the [

r

] key.  The data will be entered and the segment will be incremented by 1.  The data 

for this segment will now be displayed.  Continue this process until the last segment is programmed.  When the last 
segment is reached, the keypad will prompt you for the next location.  If you wish to exit this location before the last 
segment is reached, press the [

#

] key.  This keypress will not save the changes made to current segment, but will exit 

the location.  To proceed to the next location, press the [Police] key.  To return to the previous location, press the 
[

Fire]

 key.  To re-enter the last location, press the [

Auxiliary

] key.  

 

 

 

!

  CHARACTER DATA

: Character Data is used to enter LCD text when programming.  (See [

r

]-[

9

]-[

2

] feature for 

custom messages, page 4.)  Custom zone descriptions and messages are stored character or ASCII data type. This 
information is programmed using the bottom line of the display as a text editor.  Once a character location has been 
entered, the current data will be displayed on the bottom line.  As is always the case, the top line will display the 
current location and segment number.  The five (5) function keys, as well as the up and down arrow to the right of the 
display, are now used to edit the message prior to saving it back to the location storage.   An underscore (

_

) in the 

display indicates the current cursor location.  To move the cursor to the right, press the [

r

] key.  To move the cursor to 

the left, press the [

Cancel

] key.  To change the character at the current cursor location, press the 

Up

 or 

Down Arrow

 

until the desired character is displayed.  An alternative and possibly faster method, is to enter the 2-digit number found 
in Table 1.1 or 1.2 which corresponds to the desired character. To accept this character, press the [

r

] key.  The 

character will remain and the cursor will be advanced one space to the right.  To insert spaces, press the [

Stay

] key.   

To delete characters, press the [

Chime

] key.  To access the library, press the [

Exit

] key.  Once in the library, the 

Up

 

and 

Down Arrow

 can now be used to scroll through the library.  To make a character flash, press the [

Bypass

] key.  

While in the library mode, entering the flash [

Bypass

] key will cause the entire word to flash.  To enter the word or 

character being displayed, enter the [

r

] key.  When done editing the line, enter the [

#

] key to escape from the edit 

mode. 

Содержание CADDX NX148-E

Страница 1: ...5 SET KEYPAD OPTIONS 6 SET KEYPAD NUMBER AND PARTITION 7 KEYPAD FUNCTIONS 7 READING THE EVENT LOG 7 SET ELAPSED INCREMENTS SINCE LAST AUTOTEST 8 SET SYSTEM TIME AND DATE 8 ADJUST KEYPAD TONE 8 VIEW Z...

Страница 2: ...the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on o...

Страница 3: ...RUMPUS STAIRS WINDOW BATHROOM DURESS HEAT MICROWAVE SAFE STORAGE WING BEAM EAST HOLDUP MOTION SENSOR STUDY WIRELESS BEDROOM EMERGENCY HOUSE NORTH SHOCK TAMPER YARD BUTTON EXIT INFRARED NURSERY SHOP T...

Страница 4: ...t to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Program Mode is exited the control will enroll the devices The enrol...

Страница 5: ...keypad numbers with r 9 4 prior to programming custom messages If a keypad is added after messages are programmed you should either program ALL messages in it or enter custom message programming on an...

Страница 6: ...rt The current state of the option will be shown in the lower right corner of the display Press r to advance to the next option without making changes Otherwise follow the directions on the bottom lin...

Страница 7: ...on September 25th at 5 27 p m by user 75 The r shows that this event is not programmed to be reported to the central monitoring station POSSIBLE LOG MESSAGES 7 DISPLAY DESCRIPTION TXlobat Transmitter...

Страница 8: ...de Entry A code has been entered First Open First Open Reports when the first partition is disarmed Last Close Last Close Reports when the last partition is armed Sprnklr Sprinkler Instant sprinkler s...

Страница 9: ...r 4 6 The LCD Screen will prompt to Select Light Number 0 9 2 Enter the number of the device to edit The LCD will display the light number on the left On the right side of the display it will prompt...

Страница 10: ...X4 6 8 or 3 digit NX8E user number Remember to use leading zeros i e 03 or A003 for user 3 The LCD will now prompt you for the first in the following list of attributes PROMPTS 1 Outputs used Open Clo...

Страница 11: ...y To set the multi partition mode use the r 9 3 function and answer YES to the question Master keypad NOTE r 1 followed by a code will temporarily access the Master Mode The keypad will revert back to...

Страница 12: ...ash Area Ready to Force Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the up scroll key To arm all of the areas pre...

Страница 13: ...this display press r 2 One or more of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press Control Over Current A short circuit...

Страница 14: ...an expansion device has been opened Expansion RF Jammed A radio receiver is being jammed Expansion Trouble An expansion device or keypad is not reporting to the control panel Expansion Siren trouble...

Страница 15: ...225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 NX148 E MAXIMUM WIRE RUN Note These numbers are for one keypad at the...

Страница 16: ...0 degrees F CURRENT DRAW 110 mA Maximum 75 mA without Sounder LCD KEYPAD DIMENSIONS 6 4 Wide 5 3 High 1 0 Deep SHIPPING WEIGHT 2 lbs CADDX CONTROLS INC 1420 NORTH MAIN STREET GLADEWATER TEXAS 75647 TO...