9 4 SET KEYPAD NUMBER AND PARTITION
1) Enter [
r
]-[
9
]-[
4
]
The LCD screen will prompt “Please Enter Your Code”.
2) Enter [
program code
]
The LCD will now prompt you for the keypad number followed by
[
r
]. The current keypad number will be displayed in the lower right
hand corner.
3) Enter the keypad number followed by
[
r
]
The LCD will now prompt you for the partition number followed by
[
r
]. The current partition will be displayed in the lower right hand
corner.
4) Enter the partition number for the
keypad
The keypad will automatically exit this mode now.
KEYPAD FUNCTIONS
r
9 0 READING THE EVENT LOG
The control panel has an event log that can be retrieved using a master code. This log contains a listing of the last
185 events along with date, time, and partition where the event occurred.
1) Press
[
r
]-[9]-[0]
The LCD screen will prompt you for a code.
2) Enter [
master code
]
The LCD screen will now show the most recent event.
3) To view the events from most recent to the oldest, press the down scroll key.
4) To view the events from the oldest to the newest, press the up scroll key. The display contains the following
information.
Open
75
9/25 17:57
P3
r
Event
º
»
User or Zone ID
Date
º
»
Indicates partition and
r
indicates
(Month/Date) an
event not reported
ü
Time shown in
24-hour
format
This screen shows an opening of Partition 3 on September 25
th
at 5:27 p.m. by user 75. The [
r
] shows that this event
is not programmed to be reported to the central monitoring station.
POSSIBLE LOG MESSAGES
7
DISPLAY DESCRIPTION
TXlobat
Transmitter Low Battery - The transmitter has a low battery.
ZN Lost
Zone Lost - A wireless or multiplexed zone device is not reporting to the control.
Duress
Duress - The control has been armed or disarmed with a Duress code.
Man Fire
Manual Fire - Keypad “Fire” has been activated.
Aux 2
Auxiliary 2 - Keypad “Medical” has been activated.
Panic
Panic - Keypad “Panic” has been activated.
KP Tamper
Keypad Tamper - The keypad tamper has been activated.
BoxTamp
Box Tamper - The box tamper circuit has been activated.
AC Fail
AC Fail - AC failure has been detected.
OverCur
Over Current - A short circuit of a power supply has occurred.
Srn Tamp
Siren Tamper - A siren or speaker tamper has been detected.
Tel Flt
Telephone Fault - A telephone fault or tamper has been detected.
Exp Trb
Expansion Trouble - An expansion device or keypad is not reporting to the control.
Log Full
Log Full - The event log is full.
Open
Open - Reports user number, date, time and partition of opening .
Close
Close - Reports user number, date, time and partition of closing.
Exit Err
Exit Error - Entry/Exit zone was faulted at the instant the exit delay expired.
Rec Close
Recent Close - An alarm occurred within 5 minutes after the control was armed.
Autotest
Auto Test - Sending a communicator test at a specified interval.
Start Prog
Start Programming - Local programming is started.