LOADING FACTORY DEFAULTS

 

To load the factory defaults, enter the Program Mode for the module to be defaulted using the procedure on page 2, 
then type [

9

]-[

1

]-[

0

]-[

#

]. The keypad will beep 3 times indicating that the loading is in progress. The loading takes about 

6 seconds.  To load the factory defaults for the LCD keypad, enter the Program Mode from a 

different

 keypad (does 

not have to be LCD keypad), and follow the procedures mentioned previously.  

NOTE:  The two-line Custom and 

two-line Shutdown Messages will not be defaulted. 

 
 

 

ENROLLING MODULES AND KEYPADS

 

For supervision purposes, the NetworX control panel has the ability to automatically find and store in its memory the 
presence of all keypads, zone expanders, wireless receivers, and any other module connected to the data terminal. 
This allows these modules to be supervised by the control panel. 

NOTE

: All modules should be connected and set to 

unique addresses prior to enrolling modules. To enroll the modules, enter the Program Mode of the NetworX control 
panel.  When the Program Mode is exited, the control will enroll the devices.  The enrolling process takes about 12 
seconds, during which time the "Service Required" will be displayed.  Once a module is enrolled, if it is not detected by 
the control, the "Service Required

@

 will be displayed. 

 
 

PROGRAMMING THE NX148-E LCD KEYPADS

 

This section describes how to program the address and partition of each keypad, as well as the options that are 
available.  The address of the keypad is important because this is how the panel supervises the keypads. The factory 
default for the “Master Code” is [

1

]-[

2

]-[

3

]-[

4

] when using a 4-digit code, or  [

1

]-[

2

]-[

3

]-[

4

]-[

5

]-[

6

] for a 6-digit code.  The 

factory default for the "Go To Program" code is [

9

]-[

7

]-[

1

]-[

3

] when using a 4-digit code, or [

9

]-[

7

]-[

1

]-[

3

]-[

0

]-[

0

] for a 6-

digit code. 

 

USING THE FUNCTION MENU

 

Many of the functions shown below are in the Function Menu. Press [

r

] to access this menu. Once the [

r

] key is 

depressed, the display will begin scrolling though a list of functions and the corresponding number(s) associated with 
those functions.

 

To access a function press the number(s) listed for that function. If you already know the function 

numbers simply press [

r

] followed by the function number.  

NOTE

: Some of the functions are not listed because they are installer-level functions. 

 

 

 

These are samples of the displays that will appear in the Function 
Menu. Each time the [

r

] key is pressed the next menu item will be 

displayed.  Press the number or key to access the function desired. 
Press the [#] key to exit. 

Select an Option 
Press 

 for Help 

 

 

Select an Option 

ù

=Zone Review 

 

 

Содержание CADDX NX148-E

Страница 1: ...5 SET KEYPAD OPTIONS 6 SET KEYPAD NUMBER AND PARTITION 7 KEYPAD FUNCTIONS 7 READING THE EVENT LOG 7 SET ELAPSED INCREMENTS SINCE LAST AUTOTEST 8 SET SYSTEM TIME AND DATE 8 ADJUST KEYPAD TONE 8 VIEW Z...

Страница 2: ...the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on o...

Страница 3: ...RUMPUS STAIRS WINDOW BATHROOM DURESS HEAT MICROWAVE SAFE STORAGE WING BEAM EAST HOLDUP MOTION SENSOR STUDY WIRELESS BEDROOM EMERGENCY HOUSE NORTH SHOCK TAMPER YARD BUTTON EXIT INFRARED NURSERY SHOP T...

Страница 4: ...t to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Program Mode is exited the control will enroll the devices The enrol...

Страница 5: ...keypad numbers with r 9 4 prior to programming custom messages If a keypad is added after messages are programmed you should either program ALL messages in it or enter custom message programming on an...

Страница 6: ...rt The current state of the option will be shown in the lower right corner of the display Press r to advance to the next option without making changes Otherwise follow the directions on the bottom lin...

Страница 7: ...on September 25th at 5 27 p m by user 75 The r shows that this event is not programmed to be reported to the central monitoring station POSSIBLE LOG MESSAGES 7 DISPLAY DESCRIPTION TXlobat Transmitter...

Страница 8: ...de Entry A code has been entered First Open First Open Reports when the first partition is disarmed Last Close Last Close Reports when the last partition is armed Sprnklr Sprinkler Instant sprinkler s...

Страница 9: ...r 4 6 The LCD Screen will prompt to Select Light Number 0 9 2 Enter the number of the device to edit The LCD will display the light number on the left On the right side of the display it will prompt...

Страница 10: ...X4 6 8 or 3 digit NX8E user number Remember to use leading zeros i e 03 or A003 for user 3 The LCD will now prompt you for the first in the following list of attributes PROMPTS 1 Outputs used Open Clo...

Страница 11: ...y To set the multi partition mode use the r 9 3 function and answer YES to the question Master keypad NOTE r 1 followed by a code will temporarily access the Master Mode The keypad will revert back to...

Страница 12: ...ash Area Ready to Force Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the up scroll key To arm all of the areas pre...

Страница 13: ...this display press r 2 One or more of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press Control Over Current A short circuit...

Страница 14: ...an expansion device has been opened Expansion RF Jammed A radio receiver is being jammed Expansion Trouble An expansion device or keypad is not reporting to the control panel Expansion Siren trouble...

Страница 15: ...225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 NX148 E MAXIMUM WIRE RUN Note These numbers are for one keypad at the...

Страница 16: ...0 degrees F CURRENT DRAW 110 mA Maximum 75 mA without Sounder LCD KEYPAD DIMENSIONS 6 4 Wide 5 3 High 1 0 Deep SHIPPING WEIGHT 2 lbs CADDX CONTROLS INC 1420 NORTH MAIN STREET GLADEWATER TEXAS 75647 TO...

Отзывы: