6) Press [
#
] to exit this function.
r
4 9 CHANGE LANGUAGES
1) Enter [
r
]-[
4
]-[
9
]
The LCD keypad is now toggled to the second language. If you
enter [
r
]-[
4
]-[
9
] again, the keypad will revert to the first language.
r
5
CHANGING USER CODES
Note:
For partitioned systems, someone changing the code of another person must have access to all or more
partitions than the user being changed.
1) Enter [
r
]-[
5
]
The LCD Screen will prompt for a code.
2) Enter [
master code
]
The LCD Screen will prompt for a user number.
3) Enter the 2-digit (applies to NX4/6/8) or
3-digit (NX8E) user number. Remember
to use leading zeros, i.e. "03" or
A
003"
for user 3.
The LCD screen will prompt for a new code.
4) Enter the new user code designated for that individual. The sounder will beep 3 times if it rejects the code.
5) If another user code needs to be programmed, return to step 3.
6) To exit Code Programming, press [
#
] while the LCD screen is prompting for a new user number.
r
6
ASSIGNING AUTHORITY LEVEL
Note
: You must have authority to the partition you wish to add or remove from another person’s authority.
1) Enter [
r
]-[
6
]
The LCD Screen will prompt for a code.
2) Enter [
master code
]
The LCD Screen will prompt for a user number.
3) Enter the 2-digit (applies to NX4/6/8) or
3-digit (NX8E) user number. Remember
to use leading zeros, i.e. "03" or
A
003"
for user 3.
The LCD will now prompt you for the first in the following list of
attributes.
PROMPTS
(#1) Outputs used?
Open / Close Rprt?
Bypass enable?
Arm / Disarm?
If Prompt #1 ("Outputs used?") is
answered NO, the LCD will display the
four messages below.
If Prompt #1 ("Outputs used?") is
answered YES, the LCD will display the
four messages below.
Master code?
Output 4 enable?
Sched arm only?
Output 3 enable?
Arm only?
Output 2 enable?
Reserved
Output 1 enable?
4) Enter a partition number.
NOTE
: The default allows access to
all
partitions. The first keypress will remove access
to the partition. To reestablish access, press the partition number again.
5) Press [
r
] when completed.
The LCD Screen will prompt you for the next user code.
6) If another user code needs to be programmed, return to Step 3.
7) To exit this feature, press [
#
].
NOTE TO INSTALLER: Any master arm/disarm code can add or change a user code if the master code has
access to the same partitions as the code being added/changed. Consequently, when programming the user
codes for a partitioned system, leave at least one code access to all partitions or you will not be able to add
new users
(can be "go to program code" if enabled in location 43 of the control panel). If you desire the end
user to be able to add new codes, you must remove the partition authority from all blank codes.
10