Description 

The AS520 series siren is an outdoor siren with two beacons. 

Wiring 

First, wire the control panel (power down) to the siren as 
shown above, before connecting the battery. When the battery 
is connected for the first time, the siren will give a short beep. 
The siren cannot be activated until all inputs (input power and 
hold-off voltages) are correct. The siren will be activated if the 
input power is removed or drops significantly or if the siren 
hold-off voltage is removed. 

Specifications 

Supply* 

10.0 to 14.5 V

 

Current 
 

Standby 

 

Operating 

 
40 mA typical 
350 mA typical (including beacon) 

Sound output 

114 dB at 1 m, 85 dB at 3 m 

Frequency 

1.8 to 3 kHz 

Cut-off timer 

Preset at 3 min 
Adjustable 5, 10, 20 min 

Battery: 
 

Type 

 

Load voltage 

 
Lead acid, BS121N, 12 V, 1.2 Ah 
13.6 to 14.2 V

 

Tamper 

28 V

, 100 mA max. 

Weight 

1 kg 

Dimensions 

210 x 300 x 70 mm 

Working temperature 

−25 to +55°C (no battery) 
0 to +40

°C (with battery) 

Beacon 

 

Operating current 

110 mA 

Light output 

100.000 peak lumens 

Life time 

1.000.000 flashes 

Flash rate 

60/minute 

Spike suppression 
network 

Standard fitted 

To be connected to an external current limited power supply. 
(Advised: 5 A). 

Battery removal/disposal 

This product may contain one sealed, rechargeable, BS-type 
lead-acid battery. Because removing batteries may affect the 
product's configuration settings or trigger an alarm, only a 
qualified installer should remove them. 

To remove the battery: 

1.  Make sure that your product settings allow you to open its 

cover without starting the tamper alarm. 

2.  Switch off the mains power, if necessary, and remove the 

cover. 

3.  Disconnect battery connectors. 
4.  Remove the battery from the holder. 

For proper recycling, dispose of all batteries as required by 
local ordinances or regulations. 

WARNING: 

Danger of explosion if battery is incorrectly 

replaced. Replace only with the same or equivalent type 
recommended by the manufacturer.

 

Regulatory information 

Manufacturer 

PLACED ON THE MARKET BY: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 

AUTHORIZED EU REPRESENTATIVE: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Certification 

 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR SALE 
TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. UTC FIRE & SECURITY 
CANNOT PROVIDE ANY ASSURANCE THAT 
ANY PERSON OR ENTITY BUYING ITS 
PRODUCTS, 

INCLUDING ANY “AUTHORIZED 

DEALER” OR “AUTHORIZED RESELLER”, IS 
PROPERLY TRAINED OR EXPERIENCED TO 
CORRECTLY INSTALL FIRE AND SECURITY 
RELATED PRODUCTS. 

For more information on warranty disclaimers and 
product safety information, please check 

https://firesecurityproducts.com/policy/product-
warning/

 or scan the QR code. 

European Union 
directives 

UTC Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of the Directive 
2014/30/EU and/or 2014/35/EU. For more 
information see www.utcfireandsecurity.com or 
www.interlogix.com. 

Содержание AS520 Series

Страница 1: ...ire Security Americas Corporation Inc 1 10 P N 144200999 2 ML REV D ISS 29MAR19 AS520 Series Outdoor Siren Installation Sheet EN DE ES FR IT NL PT 1 3 2 J10 J8 J9 Tamper hole Tamper BS121N AB570 Optio...

Страница 2: ...t may be illegal to dispose of this battery improperly under local state or federal laws Check with your local authorities for disposal and recycling options III 1K UK IRL only 1K Cut J10 to disable t...

Страница 3: ...r an alarm only a qualified installer should remove them To remove the battery 1 Make sure that your product settings allow you to open its cover without starting the tamper alarm 2 Switch off the mai...

Страница 4: ...hlen 5 A Batterie Ausbau Entsorgung Dieses Produkt kann eine versiegelte wiederaufladbare BS Typ Bleigelbatterie enthalten Da das Entfernen von Batterien die Zentralenkonfiguration beeintr chtigen ode...

Страница 5: ...rla a cabo un instalador cualificado ya que esto podr a afectar a la configuraci n del producto o activar una alarma Para extraer la bater a realice lo siguiente 1 Compruebe que la configuraci n de su...

Страница 6: ...otection 2 Retirer l alimentation secteur si n cessaire et retirer le couvercle 3 D connecter la batterie 4 Retirer la batterie de son support Pour un recyclage propre entreposer toutes les batteries...

Страница 7: ...osione se la batteria sostituita incorrettamente Sostituire solo con lo stesso modello o uno equivalente come raccomandato dal fornitore Certificazione e conformit Costruttore MESSO SUL MERCATO DA UTC...

Страница 8: ...OOR UTC Fire Security Americas Corporation Inc 3211 Progress Drive Lincolnton NC 28092 USA GEAUTORISEERDE EU VERTEGENWOORDIGER UTC Fire Security B V Kelvinstraat 7 6003 DH Weert Nederland Certificatie...

Страница 9: ...o reguladora Fabricante COLOCADO NO MERCADO POR UTC Fire Security Americas Corporation Inc 3211 Progress Drive Lincolnton NC 28092 USA REPRESENTANTE EU AUTORIZADO UTC Fire Security B V Kelvinstraat 7...

Страница 10: ...10 10 P N 144200999 2 ML REV D ISS 29MAR19...

Отзывы: