68
ERROR - Series of beeps and error messages display.
Message
Explanation and Solution
Base 64 KB Memory Error
Memory failure in the first 64 KB. Remove
and reinstall the DIMM(s). If error
persists, replace the DIMM(s).
Timer Not Operational
Memory failure in the first 64 KB, or Timer
1 on the system board is not functioning.
Call the Customer Response Center.
Processor Error
The CPU on the system board generated an
error. Call the Customer Response Center.
8042 - Gate A20 Failure
The BIOS cannot switch to protected mode.
Call the Customer Response Center.
Processor Exception Interrupt
The CPU generated an exception interrupt.
Call the Customer Response Center.
Display Memory Read/Write Error
The sound controller is faulty. Call the
Customer Response Center.
ROM Checksum Error
The ROM checksum value does not match
the value encoded in the BIOS. Call the
Customer Response Center.
CMOS Shutdown Register Read/Write
Error
The shutdown register for CMOS RAM
failed. Call the Customer Response Center.
Cache Error/External Cache Bad
The external cache is faulty. Call the
Customer Response Center.
ERROR - Does not boot from drive A:.
Reason
Solution
Corrupt boot disk, or boot disk does not have
correct boot utilities.
Replace the boot disk. See the online
System Reference.
The boot sequence may be set to C, A, in
which case the machine will not boot from
A if there is an operating system on C.
Change the boot sequence. See
Chapter 5.
Corrupt BIOS on the flash EPROM.
Reprogram the BIOS. See Chapter 5.