Troubleshooting
29
Chapter 4
Troubleshooting and Problem Solving
4.1 Overview
The SS-1200-FCAL Enclosure includes a processor and associated monitoring and control logic to enable it to
diagnose problems within the enclosure’s power, cooling and drive systems.
The Enclosure Services Processor is housed along with the Operator Panel either in the front or rear of the enclosure.
The sensors for power, cooling and thermal conditions are housed within the Power Supply/Cooling modules. There
is independent monitoring for each unit.
If a fault is indicated on the Operator Panel (Ops Panel), please refer firstly to
Table 4–1
and then to the section
referenced within that table.
4.2 LEDs
Green LEDs are always used for good or positive indication, flashing Green/Amber if non-critical conditions exist.
Amber LEDs indicate there is a critical fault present within the module.
The Operator Panel displays the aggregated status of all the modules. The Ops Panel LEDs are shown in
Figure 4–
1
and the LED status conditions are listed in
Table 4–1
.
Table 4–1 Ops Panel LED Status
LED
Off
Green Steady
Green/Amber
Flashing
Amber
Steady Section
Ref No.
System Status
Power off or
Standby
ESI functions all
OK
System
Configuration
Error
ESI / I2C
function failure
4.5.1
Drive Status
Power off/
Standby
No fault reported
Not used
Drive fault
reported
4.6
Содержание Fibre Channel
Страница 3: ...SS 1200 FCAL Rack Installation and User Guide Part No 19933 01 Issue 1 0 June 01 1998 ...
Страница 22: ...SS 1200 FCAL User Guide 12 ...
Страница 34: ...SS 1200 FCAL User Guide 24 ...
Страница 48: ...SS 1200 FCAL User Guide 38 ...
Страница 53: ...SS 1200 FCAL LRC Input Output Module Installation Guide Part No 19934 01 Issue 1 0 June 01 1998 ...
Страница 56: ...iv FCAL LRC I O Module ...
Страница 66: ...FCAL LRC I O Module 8 ...
Страница 69: ...SS 1200 FCAL Drive Carrier Module Installation Guide Part No 19935 01 Issue 1 0 June 01 1998 ...
Страница 72: ...iv FC AL Drive Module ...
Страница 82: ...FCAL Drive Module 8 ...