Getting Started
19
2.3.5
ESI/Ops Panel Module Installation
2.3.5.1
Parts Check List
• Front ESI/Ops Panel Module OR Rear ESI/Ops Panel Module
• Ops panel key(s)
• Jumper 2 pin
2.3.5.2
Manual Spin-up Jumper
This jumper is provided to disable the auto spin start function.
Caution
If this jumper is fitted the Enclosure services will not attempt to auto start any of the drives in the
enclosure.
2.3.5.3
Jumper Installation Procedure
1
The jumper is fitted at the rear of the ESI/Ops Panel module, to access it the module must be removed from the
enclosure.
2
Fit the jumper on the 2 pins (designated LK1) on the ESI motherboard to disable the auto spin start function.
Figure 2–6
Fitting the Earth Screw
Table 2–3 Jumper Connections
ESI Motherboard Pin
Condition
LK1
Fitted - Manual start, no auto spin-up
Not Fitted - Auto spin-up
LK2
Reserved: DO NOT USE