33
6. Set the drive into the tray and secure it with two screws on each side.
Screws (Two
each side)
7. Attach the slot filler to the drive tray.
8. Slide the drive into the slot and secure it to the vertical bay.
9. Remove the disk drive fan.
10. Connect the power cable and SCSI cable to the drive.
11. Replace the disk drive fan.
12. Close the base unit and restart the system.
13. If necessary, install the appropriate device driver and configure the device according to the
vendor’s instructions.
To install a drive into the front horizontal slots:
1. For SCSI devices, disable the SCSI termination, and set the SCSI ID for the drive to an unused
number.
2. Remove the top cover from the base unit as described in Chapter 1.
Drive Tray
Slot Filler
Screws