I N T E R F AC E M O D E L 9 8 4 0
MO D E L 9 8 4 0 P G 3 8
P U B .
6 0 3 2 - 0 1
The format for the CB commands is:
For backward compatibility:
CB1(space)(channel)(serial number)#
Alternatively, to delineate between a Load and a Torque Cell:
CB1(cell type)(channel)(serial number)#
CB2(space)(month)(day)(year)
CB3(space) (excitation)(calibration unit)
CB4(space)(rated load)#
where cell type is 0 for load and 1 for torque, channel is A or B, serial number is the
serial number of the cell, not exceeding 8 characters, month, day, and year are 2 digit
numbers to represent the current date, excitation should be a 0 for 5.00 volts or a 1 for
10.00 volts, and calibration unit is the desired unit for this calibration, and rated load is
the maximum load or torque rating for the cell.
Example 1:
@123CB1 A123456#
Acknowledge 1:
@ 123 Calibrate Begin 1 Command – New
Load Cell S/N: 123456 – Channel A
Example 1A:
@123CB11A123456#
Acknowledge 1:
@ 123 Calibrate Begin 1 Command – New
Torque Cell S/N: 123456 – Channel A
Example 2:
@123CB2 042298
Acknowledge 2:
@ 123 Calibrate Begin 2 Command – New
Cal Date: Apr22-98
Example 3:
@123CB3 100
Acknowledge 3:
@ 123 Calibrate Begin 3 Command – New
Excitation Voltage: 10.0 V, Calibration Unit: Lb
Example 4:
@123CB4 1000.0#
Acknowledge 4:
@ 123 Calibrate Begin 4 Command – New