I N T E R F AC E M O D E L 9 8 4 0
MO D E L 9 8 4 0 P G 4 8
P U B .
6 0 3 2 - 0 1
Option View Command (OV)
The Option View (OV) command returns a list of the current settings of all the system
options. The format is OV.
Example:
@123OV
Acknowledge:
@ 001 Auto Identify is on
Auto Identify Annunciator is on
TEDS is on
Auto Tare is on
Auto Zero Channel A is off
Auto Zero Channel B is off
Auto Zero Channel C is off
Auto Zero Channel D is on
Com Address is 001
Com Baud Rate is 9600
Com Line Feed is on
Retain Tare is off
Freeze Display is off
RS232 End of Transmission Character is off
Option Printer
OPT
Baud Rate
Command (OP)
The Option Printer Baud Rate (OP) command is used to select the printer baud rate.
The format is OP(code) where the code is from the table shown at the right.
Example:
@123OP9
Acknowledge:
@ 123 Printer Baud Rate is 230.4K
Option Auto-Identify Command (OI)
The Option auto-Identify (OI) command is used to turn
auto-identification of load cells on or off. The format is
OI(0 or 1), where 0 turns auto-id off, and 1 turns auto-
id on.
Example:
@123OI0
Acknowledge:
@ 123 Auto Identify is off
Option Printer
Command
Code
Baud Rate
4
4800
5
9600
6
19.2K
8
57.6K
9
230.4K