16 Ga. Medium Crown Stapler
Drives 7/16" Crown Staples (1" to 2" / 25 to 51mm)
Model No. SN5016
Item No. 64405
11
Interchange Brands
Operator’s Manual
If an inline lubricator is not used, a few drops of oil will need to be added to
the air inlet before each use .
3 .
AIR HOSE
Air hose must be professional grade and have a minimum working pressure
rating of 150psi or 150% of the maximum pressure produced in the system,
whichever is higher .
Operating Pressure
1 .
OPERATING PRESSURE RECOMMENDATIONS
Recommended operating pressure is 70 to 120 psi / 5 to 8 .5 kgs .
Select the operating pressure within this range for the best fastener
performance . The staple length and thickness and the hardness of the wood
are factors in determining what the pressure should be set at .
The correct air pressure is the lowest pressure which will do the job . Using
the stapler at a higher than required air pressure unnecessarily over
stresses the stapler .
Do not exceed this recommended operating pressure .
Lubrication
It is important that the tool be properly lubricated . Without proper lubrication, the tool
will not work properly and parts will wear prematurely .
Use INTERCHANGE pneumatic tool lubricant . Do not use detergent oil or
additives . These lubricants will harm the O-rings and other rubber parts . This
will cause the tool to malfunction .
Filter-regulator-lubricator units should always be used . Keep the lubricator
filled with INTERCHANGE pneumatic tool lubricant .
If a lubricator is not available, supply 3 to 5 drops of INTERCHANGE
pneumatic tool lubricant into the air plug on the tool twice a day .
Directional Exhaust Cover
(on some models)
WARNING:
Always disconnect air supply
before rotating the exhaust cover .
■
Rotate Cover by Unscrewing
Loosen screw as shown . Adjust
to desired exhaust direction and
tighten screw .
■
Rotate Cover by Hand
Direction of the exhaust air can be
changed by rotating exhaust cover
by hand .