background image

16 Ga. Medium Crown Stapler 

Drives 7/16" Crown Staples (1" to 2" / 25 to 51mm)

Model No. SN5016 

Item No. 64405

11

Interchange Brands  

Operator’s Manual

 

„

If an inline lubricator is not used, a few drops of oil will need to be added to 

the air inlet before each use .

3 . 

AIR HOSE 

Air hose must be professional grade and have a minimum working pressure 

rating of 150psi or 150% of the maximum pressure produced in the system, 

whichever is higher .

Operating Pressure

1 . 

OPERATING PRESSURE RECOMMENDATIONS

 

„

Recommended operating pressure is 70 to 120 psi / 5 to 8 .5 kgs .

 

„

Select the operating pressure within this range for the best fastener 

performance . The staple length and thickness and the hardness of the wood 

are factors in determining what the pressure should be set at .

 

„

The correct air pressure is the lowest pressure which will do the job . Using 

the stapler at a higher than required air pressure unnecessarily over 

stresses the stapler .

 

„

Do not exceed this recommended operating pressure .

Lubrication

It is important that the tool be properly lubricated . Without proper lubrication, the tool 

will not work properly and parts will wear prematurely .

 

„

Use INTERCHANGE pneumatic tool lubricant . Do not use detergent oil or 

additives . These lubricants will harm the O-rings and other rubber parts . This 

will cause the tool to malfunction .

 

„

Filter-regulator-lubricator units should always be used . Keep the lubricator 

filled with INTERCHANGE pneumatic tool lubricant .

 

„

If a lubricator is not available, supply 3 to 5 drops of INTERCHANGE 

pneumatic tool lubricant into the air plug on the tool twice a day .

Directional Exhaust Cover

(on some models) 

WARNING: 

Always disconnect air supply 

before rotating the exhaust cover .

 

Rotate Cover by Unscrewing

 

„

Loosen screw as shown . Adjust 

to desired exhaust direction and 

tighten screw .

 

Rotate Cover by Hand 

 

„

Direction of the exhaust air can be 

changed by rotating exhaust cover 

by hand .

Содержание SN5016

Страница 1: ...Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the MANUAL be kept readily available as an important refer ence when using this tool Medium Crow...

Страница 2: ...ation 5 Accessories 5 Safety Information Safety Instructions 6 9 Employer s Responsibilities 9 Operating the Stapler Air Supply Connections Operating Pressure 10 11 Lubrication 11 Directional Exhaust...

Страница 3: ...Y Most accidents that result from the operation and maintenance of staplers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a pot...

Страница 4: ...ded Operating Pressure 70 to 120 psi 5 to 8 5 kgs Applications Wall Sheathing Subflooring Roof Decking Furniture Frames Crate and Box Assembly and Vinyl Siding Staple Specifications FASTENERS 16 ga 06...

Страница 5: ...Medium Crown Stapler Drives 7 16 Crown Staples 1 to 2 25 to 51mm Model No SN5016 Item No 64405 5 Interchange Brands Operator s Manual Accessories STANDARD ACCESSORIES Parts Identification 1 Eye Protec...

Страница 6: ...rs from loud noise Wear head protection to protect your head from flying objects 3 KEEP FACE HANDS AND FEET AWAY FROM FIRING HEAD AT ALL TIMES Never place your face hands or feet near the firing head...

Страница 7: ...pler appears to be operating unusually is making strange noises has parts missing or appears to be defective stop using it immediately and arrange for repairs by an authorized service center 15 CHECK...

Страница 8: ...FUL OF DOUBLE FIRING DUE TO RECOIL If the safety push lever is unintentionally allowed to re contact the work piece following recoil an unwanted fastener will be driven In order to avoid this undesira...

Страница 9: ...o tool malfunction and resulting injuries Only authorized service personnel should repair the stapler 32 NEVER MODIFY OR ALTER A STAPLER Doing so may cause it to malfunction and personal injuries may...

Страница 10: ...19 3 Safety Standard for Compressors for Process Industries Moisture or oil in the air compressor may accelerate wear and corrosion in the stapler Drain daily Connections 1 Fittings Install a female...

Страница 11: ...a higher than required air pressure unnecessarily over stresses the stapler Do not exceed this recommended operating pressure Lubrication It is important that the tool be properly lubricated Without...

Страница 12: ...h the safety push lever and does not operate unless the safety push lever is depressed upward position There are two methods of operation to drive staples with this Stapler Single Fire The switch loca...

Страница 13: ...dy to operate Staple Loading WARNING NEVER connect stapler to pressure which potentially exceeds 150psi NEVER USE NON RELIEVING COUPLER ON STAPLER The stapler and air hose must have a hose coupler so...

Страница 14: ...e air pressure to 70psi Connect the air hose Do not load any staples in the stapler THE STAPLER MUST NOT LEAK AIR Hold the stapler downward and pull the trigger THE STAPLER MUST NOT LEAK AIR 3 Remove...

Страница 15: ...damaged Piston O ring worn or damaged Replace with Genuine staples Replace staple feeder Replace ribbon spring Replace O ring Staples jam driven staple is bent Check for proper staples Driver blade w...

Страница 16: ...performed Drain air line filter daily Keep lubricator filled Clean filter element then blow air through filter in direction opposite to normal flow Clean magazine and feeder mechanism Keep safety pus...

Страница 17: ...Crown Stapler Drives 7 16 Crown Staples 1 to 2 25 to 51mm Model No SN5016 Item No 64405 17 Interchange Brands Operator s Manual PARTS DRAWING SCHEMATICS FOR SN5016 Parts Drawing Schematics Parts List...

Страница 18: ...3X15 20 321920 DRIVER BLADE Loctite 262 69 320880 CONTACT PLATE 21 310370 PISTON 70 620370 SPRING 22 510510 O RING 37 5X3 55 71 110190 ADJUST BUTTOM 23 310180 CYLINDER 72 640010 ROLL PIN 2X8 24 520130...

Страница 19: ...SN5016 98516 SN5016K7 Kit 7 Safety Kit for SN5016 98517 SN5016K8 Kit 8 Feeder Kit for SN5016 WARNING Always follow the tool manufacturer s safety and maintenance instructions Always wear safety glass...

Страница 20: ...this war ranty 4 Labor charges maintenance or loss damage and repairs resulting from im proper operation are not covered by this warranty GENERAL WARRANTY CONDITIONS This warranty will be honored only...