18
PSI 9000 2U Series
© 2015 Intepro Systems, LP. Specifications subject to change without notice.
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display error adds to the error of the related actual value on the DC output
3000 W
Model 2U
PSI 9040-120
PSI 9080-120
PSI 9200-50
AC Input
Input voltage
180...264 V AC
180...264 V AC
180...264 V AC
- with additional derating
180...207 V AC
180...207 V AC
180...207 V AC
Input connection
1ph,N,PE
1ph,N,PE
1ph,N,PE
Input frequency
50/60 Hz
50/60 Hz
50/60 Hz
Input fuse (internal)
T16 A
T16 A
T16 A
Leak current
< 3.5 mA
< 3.5 mA
< 3.5 mA
Power factor
> 0.99
> 0.99
> 0.99
DC Output
Max. output voltage U
Max
40 V
80 V
200 V
Max. output current I
Max
120 A
120 A
50 A
Max. output power P
Max
3000 W
3000 W
3000 W
Max. output power P
Max
with derating
2500 W
2500 W
2500 W
Overvoltage protection range
0...44 V
0...88 V
0...220 V
Overcurrent protection range
0...132 A
0...132 A
0...55 A
Overpower protection range
0…3300 W
0…3300 W
0…3300 W
Temperature coefficient for set
values Δ/K
Voltage / current: 100 ppm
Voltage regulation
Adjustment range
0...40 V
0...80 V
0...200 V
Accuracy
(1
(at 23 ± 5°C)
< 0.1% U
Nom
< 0.1% U
Nom
< 0.1% U
Nom
Stability at ±10% ΔU
AC
< 0.02% U
Nom
< 0.02% U
Nom
< 0.02% U
Nom
Stability at 0...100% load
< 0.05% U
Nom
< 0.05% U
Nom
< 0.05% U
Nom
Rise time 10...90%
Max. 30 ms
Max. 30 ms
Max. 30 ms
Display: Resolution
See section
“1.9.6.4. Resolution of the displayed values”
Display: Accuracy
(4
≤ 0.2% U
Nom
≤ 0.2% U
Nom
≤ 0.2% U
Nom
Ripple
(2
< 114 mV
PP
< 8 mV
RMS
< 114 mV
PP
< 8 mV
RMS
< 164 mV
PP
< 34 mV
RMS
Remote sensing compensation
Max. 5% U
Nom
Max. 5% U
Nom
Max. 5% U
Nom
Output voltage fall time (at no load)
after switching DC output off
-
-
Down from 100% to
<60 V: less than 10 s
Current regulation
Adjustment range
0...120 A
0...120 A
0...50 A
Accuracy
(1
(at 23 ± 5°C)
< 0.2% I
Nom
< 0.2% I
Nom
< 0.2% I
Nom
Stability at ±10% ΔU
AC
< 0.05% I
Nom
< 0.05% I
Nom
< 0.05% I
Nom
Stability at 0...100% ΔU
OUT
< 0.15% I
Nom
< 0.15% I
Nom
< 0.15% I
Nom
Ripple
(2
< 158 mA
PP
< 158 mA
PP
< 32 mA
PP
Display: Resolution
See section
“1.9.6.4. Resolution of the displayed values”
Display: Accuracy
(4
≤ 0.2% I
Nom
≤ 0.2% I
Nom
≤ 0.2% I
Nom
Compensation 10%->90% load
< 1.5 ms
< 1.5 ms
< 1.5 ms
Power regulation
Adjustment range
0…3000 W
0…3000 W
0…3000 W
Accuracy
(1
(at 23 ± 5°C)
< 1% P
Nom
< 1% P
Nom
< 1% P
Nom
Stability at ±10% ΔU
AC
< 0.05% P
Nom
< 0.05% P
Nom
< 0.05% P
Nom
Stability at 10-90% ΔU
OUT
* ΔI
OUT
< 0.75% P
Nom
< 0.75% P
Nom
< 0.75% P
Nom
Display: Resolution
See section
“1.9.6.4. Resolution of the displayed values”
Display: Accuracy
(4
≤ 0.8% P
Nom
≤ 0.8% P
Nom
≤ 0.85% P
Nom
Efficiency
(3
~ 92%
~ 92%
~ 93%