5.1   Installation place

There is combustible gas leakage.
There is much oil  (including engine oil) ingredient.

Please keep away from the following place, or malfunction of the
machine may be caused:

There is salty air surrounding(near the coast)
There is caustic gas (the sulfide, for example) existing in the
air (near a hotspring)
A place the heat air expelled out from the outdoor unit can
reach your neighbor’s window.

A  place that the noise  interferes your neighbors every day
life.
A  place that is too weak to bear  the weight of the unit
Uneven place.
Insufficient ventilation place.

Near a private power station or high Frequency equipment.

LP

1      Compressor

2      4-Way Valve
3      Accumulatior
4      Air Side Heat Exchanger
5      Electronic Expansion Valve
6      Storage Tank
7      Strainer
8      Water Side Heat Exchanger
        (Plate Heat Exchange)

HP

1

3

10

2

4

6

7

7

5

8

11

9

9      Differential Pressure Switch

10    High Pressure Switch
11    Low Pressure Switch
12    Discharge Gas thermistor
13    thermistor For Outdoor Temperature
14    Thermistor For Evaporation In Heating

        (Thermistor For Condenser In Cooling)

15    Thermistor For Plate Heat Exchange 1
16    Thermistor For Plate Heat Exchange 2

12

13

14

15

16

17

18

Cooling
Heating

17    Thermistor For Water Outlet
18    Thermistor For Water Inlet
19    Automatic Discharge Valve

20    Expansion Tank
21    Circulating Pump
22    Pressure Gauge
23    Safety Valve
24    Auto-watet replenishing

19

20

21

22

23

24

A

Keep  indoor  unit,  outdoor  unit,  power  supply  wiring  and
transmission wiring at least 1 meter away from televisions
and  radios.  This  is  to  prevent  image  interference  and
noise  in  those  electrical  appliances.  (Noise  may  be
generated  depending  on  the  conditions  under  which  the
electric wave is generated, even if 1 meter is kept.)

CAUTION

The insulation  of  the metal parts of the building and the air
conditioner should comply with the regulation of National Electric
Standard.

Install indoor unit, outdoor unit, power cord and connecting
wire at least 1m away from TV set or radio to prevent noise or
picture interference.

Содержание IMCH-036KC-3

Страница 1: ...MINI CHILLER MAN IO IMCH 0615 intensity mx INSTALLATION OWNER S MANUAL IMCH 036KC 3 IMCH 060KC 3 3 and 5 Tons...

Страница 2: ...result in cutting injuries Never inspect or service the unit by yourself Ask a qualified service person to perform this work Do not dispose this product as unsorted municipal waste Collection of such...

Страница 3: ...ide Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensitive to chemicals Do not place appliances which produce open...

Страница 4: ...LowPressureSwitch 12 DischargeGasthermistor 13 thermistor For Outdoor Temperature 14 Thermistor For EvaporationInHeating Thermistor For Condenser InCooling 15 Thermistor For PlateHeat Exchange1 16 The...

Страница 5: ...Never hold the inlet of the outdoor unit to prevent it from deforming 5 4 Water Outlet Reserve water outlet Reserve water outlet Water Outlet Outlet for power and connecting pipes Need to knock open...

Страница 6: ...containinganti freeze or covered by specific legislation must be fitted with hydraulic disconnectors The manufactureris not liable for obstruction breakage or noise resulting from the failure to insta...

Страница 7: ...circuit contains anti freeze it should not be allowed to drain freely as it is pollutant It should be collected for possible reuse When draining after heat pump operation take care as the water may b...

Страница 8: ...ot equipped with pressure and temperature instruments so they need to be purchased by the user i All low positions of the water system should be provided with drainage ports to drain water in the evap...

Страница 9: ...f unit When ambient temperature lower 5 running cooling mode must be charged antifreeze Refer to upper parameters for the charged volume 0 5 10 15 20 25 Freezingpoint C Percentageof ethyleneglycol inw...

Страница 10: ...the rated power supply voltage for the unit for three phase units the unbalance between the phases must not exceed 3 If these parameters are not respected contact the electricity supply company For el...

Страница 11: ...y ACcontactor SWITCH Main control board Main control board If switch is closed the unit will be stopped forcibly Under this circumstance anti frozen protection and other protection functions are still...

Страница 12: ...wn has the highest priority In the status of remote shutdown other controllers can t start the unit SWITCH 2 If switch2 is closed the unit will shift to heating mode forcibly If switch2 breaks the uni...

Страница 13: ...ency of the compressor ON OFF and OK button 1 Press to confirm the former operation when finishing the setting work 2 Long press for 3S will recovers to factory default mode Mode choice function Funct...

Страница 14: ...quit force cooling mode The unit will enter power off mode automatically when quitting force cooling mode 2 Parameter query function To enter parameter query function Press and simultaneously for 3s...

Страница 15: ...ction Flow switch malfunction High temperature protection in heating mode Defrosting Oil return of compressor Remote control P4 P5 P6 P8 Pb C8 CH dF d0 d8 Compressor discharge temperature protection C...

Страница 16: ...huts down the compressor if the temperature measured by the heat exchanger outlet temperature sensor is less than 3 C The frost prevention temperature set point can be modified by an authorised servic...

Отзывы: