intensity IMCH-036KC-3 Скачать руководство пользователя страница 16

15

Capacity (kW)

17.0(3.8~18.0)

Rated input (W)

5850

25.4

5780

25.6

R410A

Cooling: 5°C~46°C; Heating: -15°C-27°C

Cooling: 10°C~20°C; Heating mode: 35°C~50°C

1.0MPa

3.4

(mm)

(kg)

112

W×H×D

Model

Cooling

Power supply

Refrigerant

Type

Chargeing volume

kg)

Outline dimension

N.W. of the unit

Packing dimension

Rated current (A)

Heating

18.0(4.0~19.0)

Notes: the above data is measured base on the following working condition.
Refrigeration mode under nominal working condition: Condenser air in 35

. Evaporator water in/out 12/7

 .

Heating mode under nominal working condition: Evaporator air in 7

85% R.H., Condenser water in/out 40/45

.

IMCH-036KC-3

IMCH-060KC-3

10.0(2.9~10.5)

2950

11.0(3.2~12.0)

3140

2.8

110

13.6

1082×1456×435

12.8

208/230V~ 60Hz

10.4 Shutting down for long periods

11. MAIN PARAMETERS

Pump

The electronic board includes a pump control output.The pump
starts when the assembly is powered up and at least 285 seconds
before the compressor starts up and stops 120 seconds after the
assembly shuts down.
After the first 120 seconds of pump operation when the water flow
is at full speed,the water flow alarm functions are activated
(differential pressure switch and flow switch).
With a pump connected to terminals PL and PN on the installer
terminal board.

Fan speed control

For correct operation of the unit with different outside temperatures,
the microprocessor controls the fan speed based on the pressure
reading from the pressure probe, thus enabling heat exchange to
be increased and/or decreased,maintaining the condensing or
evaporation temperature practically constant.
The fan functions independently of the compressor.

Frost prevention alarm

To prevent the water freezing and damaging the plate heat
exchanger, the microprocessor shuts down the compressor if the
temperature measured by the heat exchanger outlet temperature
sensor is less than 3°C.
The frost prevention temperature set point can be modified by an
authorised service centre only and only after verifying that the water
circuit contains antifreeze.
Tripping of this alarm shuts down the compressor but not the pump,
which remains active.
To reset normal functions,the outlet water temperature must rise to
more than +15°C.Reset is manual.

If it is previewed not to use the machine for long periods After
deactivating the chiller:
-Make sure the model is in the Power off model "        ",  or
 alternatively disconnect the unit from the power supply.
-Make sure the remote control switch is closed (if present) .
-Close the water valves.

If there is a possibility that the outside temperature may drop
below zero,there is the risk of freezing.
The water circuit MUST BE EMPTIED AND SHUT OFF
POWER (when draining after heat pump operation take care
as the water may be hot) or antifreeze must be added in the
proportion recommended by the manufacturer.

CAUTION

Capacity (kW)

Rated input (W)

Rated current (A)

6700

4800

Max. input consumption (W)

30

25.0

Max. input current (A)

(mm)

W×H×D

970×1327×400

Water flow alarm

The microprocessor provides for management of a water flow
alarm controlled by a water flow switch fitted as standard on the
appliance and a flow switch to be installed on the water delivery
piping.
This safety device may trip after the first 120 seconds of pump
operation when the water flow is up to speed.
Tripping of this alarm shuts down the compressor but not the
pump,which remains active.
To reset normal functions,the alarm contact must be deactivated
for at least 15 seconds.

When condenser temperature over than 62°C, system will shut
down,but not returns to normal operation until the condenser
temperature decreased less than 52°C.

Ambient temp

(°C)

Water inlet setting temp. range(°C)

MAX. WATER PRESSURE

Содержание IMCH-036KC-3

Страница 1: ...MINI CHILLER MAN IO IMCH 0615 intensity mx INSTALLATION OWNER S MANUAL IMCH 036KC 3 IMCH 060KC 3 3 and 5 Tons...

Страница 2: ...result in cutting injuries Never inspect or service the unit by yourself Ask a qualified service person to perform this work Do not dispose this product as unsorted municipal waste Collection of such...

Страница 3: ...ide Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensitive to chemicals Do not place appliances which produce open...

Страница 4: ...LowPressureSwitch 12 DischargeGasthermistor 13 thermistor For Outdoor Temperature 14 Thermistor For EvaporationInHeating Thermistor For Condenser InCooling 15 Thermistor For PlateHeat Exchange1 16 The...

Страница 5: ...Never hold the inlet of the outdoor unit to prevent it from deforming 5 4 Water Outlet Reserve water outlet Reserve water outlet Water Outlet Outlet for power and connecting pipes Need to knock open...

Страница 6: ...containinganti freeze or covered by specific legislation must be fitted with hydraulic disconnectors The manufactureris not liable for obstruction breakage or noise resulting from the failure to insta...

Страница 7: ...circuit contains anti freeze it should not be allowed to drain freely as it is pollutant It should be collected for possible reuse When draining after heat pump operation take care as the water may b...

Страница 8: ...ot equipped with pressure and temperature instruments so they need to be purchased by the user i All low positions of the water system should be provided with drainage ports to drain water in the evap...

Страница 9: ...f unit When ambient temperature lower 5 running cooling mode must be charged antifreeze Refer to upper parameters for the charged volume 0 5 10 15 20 25 Freezingpoint C Percentageof ethyleneglycol inw...

Страница 10: ...the rated power supply voltage for the unit for three phase units the unbalance between the phases must not exceed 3 If these parameters are not respected contact the electricity supply company For el...

Страница 11: ...y ACcontactor SWITCH Main control board Main control board If switch is closed the unit will be stopped forcibly Under this circumstance anti frozen protection and other protection functions are still...

Страница 12: ...wn has the highest priority In the status of remote shutdown other controllers can t start the unit SWITCH 2 If switch2 is closed the unit will shift to heating mode forcibly If switch2 breaks the uni...

Страница 13: ...ency of the compressor ON OFF and OK button 1 Press to confirm the former operation when finishing the setting work 2 Long press for 3S will recovers to factory default mode Mode choice function Funct...

Страница 14: ...quit force cooling mode The unit will enter power off mode automatically when quitting force cooling mode 2 Parameter query function To enter parameter query function Press and simultaneously for 3s...

Страница 15: ...ction Flow switch malfunction High temperature protection in heating mode Defrosting Oil return of compressor Remote control P4 P5 P6 P8 Pb C8 CH dF d0 d8 Compressor discharge temperature protection C...

Страница 16: ...huts down the compressor if the temperature measured by the heat exchanger outlet temperature sensor is less than 3 C The frost prevention temperature set point can be modified by an authorised servic...