After a long use, check the unit stand and fitting for
damage.

If damaged, the unit may fall and result in injury.

To avoid oxygen deficiency, ventilate the room sufficiently if
equipment with burner is used together with the air
conditioner.

Arrange the drain hose to ensure smooth drainage.

Incomplete drainage may cause wetting of the building, furniture
etc.

Never expose little children, plants or animals directly to
the air flow.

Adverse influence to little children, animals and plants may
result.

Notice to avoid places where operation noise may easily be
spread away or be enhanced.

Noise can be amplified by anything blocking the air outlet
of  outdoor unit.

Choose a proper place that the noise and hot or cold wind blown
out of the  outdoor unit will not bring inconvenience to your
neighbors and not affect the growth or animal or plant.

Recommending locate and operate the equipment at the altitude
height not exceed than 1000m.

Endurable temperature during transportation is -25 ~55 .
Such equipment could endure 70  of the maximum
temperature in 24hrs.

Do not allow a child to mount on the outdoor unit or avoid
placing any object on it.
Falling or tumbling may result in injury.

Do not operate the air conditioner when using a room fumigation
- type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of those
who are hypersensitive to chemicals.

Do not place appliances which produce open fire in places
exposed to the air flow from the unit or under the indoor unit.
It may cause incomplete combustion  or deformation of the unit
due to the heat.

Do not install the air conditioner at any place where flammable
gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.

The appliance is not intended for use by young children or infirm
persons without supervision.

Young children should be supervised to ensure that they do not
play with the appliance.

Stationary appliances not fitted with means for disconnection
from the supply mains having a contact separation in all poles
that provide full disconnection under overvoltage category III, the
instructions state that means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring
rules.

Qty.

Shape.

Unit

1  Operation panel

2. ATTACHED FITTINGS

3. MAIN PARTS OF THE UNIT

2  Water manometer
3  Automatic discharge valve

2

 

4  Axial-flow fan
5  Differential pressure switch
6  Condenser
7  Accumulater
8  Security discharge
9  Electric expansive valve
10 Plate heat exchanger

11 Electrical panel
12 High pressure switch
13 4-ways valve
14 Expansion tank
15 Pump
16 Low pressure switch
17 Storage tank
18 Compressor
19 Water supply valve

Содержание IMCH-036KC-3

Страница 1: ...MINI CHILLER MAN IO IMCH 0615 intensity mx INSTALLATION OWNER S MANUAL IMCH 036KC 3 IMCH 060KC 3 3 and 5 Tons...

Страница 2: ...result in cutting injuries Never inspect or service the unit by yourself Ask a qualified service person to perform this work Do not dispose this product as unsorted municipal waste Collection of such...

Страница 3: ...ide Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensitive to chemicals Do not place appliances which produce open...

Страница 4: ...LowPressureSwitch 12 DischargeGasthermistor 13 thermistor For Outdoor Temperature 14 Thermistor For EvaporationInHeating Thermistor For Condenser InCooling 15 Thermistor For PlateHeat Exchange1 16 The...

Страница 5: ...Never hold the inlet of the outdoor unit to prevent it from deforming 5 4 Water Outlet Reserve water outlet Reserve water outlet Water Outlet Outlet for power and connecting pipes Need to knock open...

Страница 6: ...containinganti freeze or covered by specific legislation must be fitted with hydraulic disconnectors The manufactureris not liable for obstruction breakage or noise resulting from the failure to insta...

Страница 7: ...circuit contains anti freeze it should not be allowed to drain freely as it is pollutant It should be collected for possible reuse When draining after heat pump operation take care as the water may b...

Страница 8: ...ot equipped with pressure and temperature instruments so they need to be purchased by the user i All low positions of the water system should be provided with drainage ports to drain water in the evap...

Страница 9: ...f unit When ambient temperature lower 5 running cooling mode must be charged antifreeze Refer to upper parameters for the charged volume 0 5 10 15 20 25 Freezingpoint C Percentageof ethyleneglycol inw...

Страница 10: ...the rated power supply voltage for the unit for three phase units the unbalance between the phases must not exceed 3 If these parameters are not respected contact the electricity supply company For el...

Страница 11: ...y ACcontactor SWITCH Main control board Main control board If switch is closed the unit will be stopped forcibly Under this circumstance anti frozen protection and other protection functions are still...

Страница 12: ...wn has the highest priority In the status of remote shutdown other controllers can t start the unit SWITCH 2 If switch2 is closed the unit will shift to heating mode forcibly If switch2 breaks the uni...

Страница 13: ...ency of the compressor ON OFF and OK button 1 Press to confirm the former operation when finishing the setting work 2 Long press for 3S will recovers to factory default mode Mode choice function Funct...

Страница 14: ...quit force cooling mode The unit will enter power off mode automatically when quitting force cooling mode 2 Parameter query function To enter parameter query function Press and simultaneously for 3s...

Страница 15: ...ction Flow switch malfunction High temperature protection in heating mode Defrosting Oil return of compressor Remote control P4 P5 P6 P8 Pb C8 CH dF d0 d8 Compressor discharge temperature protection C...

Страница 16: ...huts down the compressor if the temperature measured by the heat exchanger outlet temperature sensor is less than 3 C The frost prevention temperature set point can be modified by an authorised servic...