7. Configuration
13
7-1 Default Settings
The default settings for the module are taken from the internal programming, and
not the dip switches.
In
order to configure the module using the dip switches, ensure dip switch 8 is in position 1. Dip switch 8 is the
toggle for the configuration settings, with 0 being the internal programmed settings, and 1 being the dip switch
settings (see 7-2 dip switches). The internal programmed settings that the module will arrive with can be found
in the table below. Please note that the dip switches provide basic parameter settings, while the GUI software
offers more advanced options. A programming cable (Part No.K447) will be required in order to use the GUI
software, which can either be purchased from Intellitec or made using the instructions on page 14 section 7-3.