Mode
Charging Control
S6 S5
0 0
0 1
1 0
1 1
Charger mode 1
Charger mode 2
POWER mode 1
POWER mode 2
bulk→absorp on→float→recharge
bulk→absorp on→OFF→rechage (LiFePO4)
Constant Voltage by DIP S2
Constant Voltage by DIP S3
14
7-2 Dip Switches
The BBINT50 settings can be adjusted in two ways:
• By DIP switches (Basic parameters);
• Via RS-232/Intellitec MV GUI software (Basic paradvanced features/custom settings).
This chapter only describes the DIP switch settings
Use a small screwdriver to carefully set the required
settings. You may need to remove the BBINT cables
(or Terminator) to be able to access the DIP switches.
For an overview of the various DIP switch settings,
see the following three tables, where a 0 indicates
OFF or ↓ and a 1 indicates ON or ↑.
CN1
LIN
REMOTE
RS-232
TEMP.
0
1
S1
S2
S3
S4
S6
S7
S8
S5
0
1
S1
S2
S3
S4
S6
S7
S8
S5
Ensure DIP SW 8 is in position‘1' when using DIP switch settings.
Absorp on Voltage
0
S1
1
14.4V
14.7V
Float Voltage
0
S2
1
13.5V
13.8V
Recharge Voltage
0
S3
1
12V
12.8V
Charge Current
0
S4
1
100%
De-ra ng 50%