IC8P Battery Charger/Analyser
Operator Manual
battery capacity. Note the capacity reported is a
function of time elapsed and the Discharge time, and
can be greater than 100%.
Discharge Amps
Amps.
This is the constant current discharge amps that the
battery has to be discharged at.
Discharge Time
Hours and
Minutes.
This is the discharge time (usually 1 hour). The charge
does not stop when this time has elapsed but
continues. This time is used to correctly calculate the
battery capacity..
FULL DISCHARGE
Value Required
Units
Description
Nominal Volts
Volts.
The battery nominal voltage is used to determine what
power rating is required for discharge and also the
help validate the data entered.
Alarm Volts.
Volts.
When the battery voltage falls below this set point the
alarm will sound alerting the operator.
Discharge Amps
Amps
The discharge current to maintain. Note when the
battery voltage falls to below one volt the discharge
current will begin to fall due to the internal resistance
and blocking diodes used in the discharge circuit.
Discharge Time
Hours and
Minutes.
The discharge will continue for this set amount of
time.