Intelligent Charging IC8P Скачать руководство пользователя страница 17

IC8P Battery Charger/Analyser

Operator Manual

 5  Battery Charge Operation

 5.1 

Constant Voltage Charge

This   charge   mode   is   designed   primarily   for   Lead
Acid   batteries,   but   can   be   used   for   any   type   of
battery, which requires top-up charging through a
constant   potential   of   the   battery   voltage.   The
battery   will   be   charged   at   the   amount   of   amps
specified until the target voltage has been achieved.
At this point the charging amps will gradually reduce
to zero as the battery voltage is maintained. This
will   continue   until   the   charge   time   has   been
completed. The parameters for the charge are as
follows: -

Target   Volts   :

  This   is   the   constant   potential

voltage of the battery.

Charge Amps :

  This is the maximum amount of

amps  to  deliver  to  the battery.  Once  the  

Target

Volts

  has   been   reached   the   amount   of   amps

delivered to the battery will decrease.

Charge   Time   :

  This   is   the   maximum   charge

duration.

Minimum   Amps   :

  When   the   amount   of   amps

delivered to the battery falls below this value the
charge will stop. Set to zero if not required.

Amps   Rise   :

  If   the   current   should   increase   to

above this setting once the 

Target Volts

 has been

reached   the   charge   will   stop.   Set   to   zero   if   not
required.

Target Fail Time :

 If the 

Target Volts

 has not

been   reached   within   this   value   of   time   then   the
charge will stop.  Set to zero if not required.

Doc: DWG1062-06-R3 IC8P Operators manual.odt

Page 17 of 46

Copyright Material of Intelligent Charging Limited © 2018

Printed On : 20/11/19

MAINTAIN

CHARGE

CURRENT

START

TIME

TO TARGET

ELAPSED

?

TARGET

VOLTAGE

REACHED

?

NO

YES

YES

NO

CHARGE

TIME ELAPSED

?

CONTROL

AMPS TO

MAINTAIN

TARGET VOLTS

CLR KEY

PRESSED

?

TIME

TO TARGET

GT ZERO

?

NO

YES

NO

YES

NO

YES

CHARGE

AMPS LT

MIN AMPS

?

MIN AMPS

GT ZERO

?

AMPS

RISE

ABOVE

THRESHOLD

?

AMPS RISE

GT ZERO

?

STOP CHARGE

YES

NO

YES

NO

YES

NO

YES

NO

Содержание IC8P

Страница 1: ...Charger Analyser Operator Manual Doc DWG1062 06 R3 IC8P Operators manual odt Page 1 of 46 Copyright Material of Intelligent Charging Limited 2018 Printed On 20 11 19 IC8P BATTERY CHARGER ANALYSER OPER...

Страница 2: ...3 CHARGE FROM PREVIOUS DATA 20 6 Battery Capacity Test or Discharge Operation 21 6 1 Capacity Test To 100 21 6 2 Capacity Test To Target Voltage 22 6 3 Full Battery Discharge 23 6 4 Performing A Capa...

Страница 3: ...ng Display Intensity 39 10 5 Automatic screen dim 39 10 6 Printing battery serial number IC8P 39 10 7 Cooling Fan 39 11 Service And Maintenance 40 11 1 Calibration 40 11 2 Cleaning 40 11 3 Battery Bac...

Страница 4: ...4 2014 Adapted from Issue 3 IC8A Manual and added printer content 2 21 07 2015 Formatting changes 3 20 11 2019 Updated drawings and incorporated new functions from MB Doc DWG1062 06 R3 IC8P Operators...

Страница 5: ...arging capacity testing and final charging can be performed Up to 6 different charge or capacity test steps can be created and up to 4 process programs can be stored in the unit Each process step has...

Страница 6: ...and when it is terminated the display will show the amount the capacity test is complete as a percentage CAPACITY TEST TO TARGET VOLTAGE This mode will discharge the battery down to the terminal volta...

Страница 7: ...rkbench or sturdy shelf above the batteries with a loading weight of at least 5Kg The unit should be sited so that at least 5cm of airspace is available all round the sides and top of the unit to allo...

Страница 8: ...e currents are detected If the fuse breaks during a charge or capacity test immediately press STOP and remove power from the unit and disconnect the battery Failure of the fuse is an indication of a f...

Страница 9: ...er from the battery charger Doc DWG1062 06 R3 IC8P Operators manual odt Page 9 of 46 Copyright Material of Intelligent Charging Limited 2018 Printed On 20 11 19 SERIAL No Intelligent Charging Limited...

Страница 10: ...main menu the CLR key is pressed repeatedly The following flowchart illustrate the menu structure 3 1 Charging Menu Doc DWG1062 06 R3 IC8P Operators manual odt Page 10 of 46 Copyright Material of Int...

Страница 11: ...C8P Operators manual odt Page 11 of 46 Copyright Material of Intelligent Charging Limited 2018 Printed On 20 11 19 MAIN MENU CHARGE DISCHARGE PROCESS SETTINGS LIBRARY MANUAL PREVIOUS GET LIBRARY START...

Страница 12: ...P Battery Charger Analyser Operator Manual 3 3 Process Operation Menu Doc DWG1062 06 R3 IC8P Operators manual odt Page 12 of 46 Copyright Material of Intelligent Charging Limited 2018 Printed On 20 11...

Страница 13: ...elligent Charging Limited 2018 Printed On 20 11 19 MAIN MENU CHARGE DISCHARGE PROCESS SETTINGS PROCESS 1 PROCESS 2 PROCESS 3 PROCESS 4 RENAME VIEW EDIT PRINT EXECUTE REQUEST NAME NEXT STEP PREV STEP C...

Страница 14: ...MENU SET CLOCK SYSTEM PRINT DISPLAY GET CLOCK DATA CALIBRATE CONTROL RESET RESET DATE CALIBRATION DATE SET CALIBRATION ADJUST CONTROL FUNCTION PARAMETERS RESET BATT S N BATT S N YES NO CHARGE DISCHAR...

Страница 15: ...EN A CHARGE OR TEST IS IN PROGRESS AS ARCING CAN OCCUR CAUSING AN EXPLOSION FROM GASSES VENTING FROM BATTERIES BEING PROCESSED THE BATTERY SHOULD ALWAYS BE ISOLATED FROM ANY EQUIPMENT BEFORE BEING CON...

Страница 16: ...R3 IC8P Operators manual odt Page 16 of 46 Copyright Material of Intelligent Charging Limited 2018 Printed On 20 11 19 Intelligent Charging Limited 1 7 4 CLR 2 5 0 8 3 6 9 ENT A B C 16A QB IC8P SERVIC...

Страница 17: ...of amps delivered to the battery will decrease Charge Time This is the maximum charge duration Minimum Amps When the amount of amps delivered to the battery falls below this value the charge will stop...

Страница 18: ...alue of time then the charge will stop Set to zero if not required Extra Time If set to a value greater than zero the charge will continue for this Extra Time once the Target Voltage has been achieved...

Страница 19: ...step 2 Step 3 Charge Amps This is the constant current amps for step 3 Step 3 Charge Time This is the amount of time the charge is maintained for step 3 Step 4 Charge Amps This is the constant current...

Страница 20: ...and apply power to the unit From the MAIN screen select CHARGE followed by MANUAL Enter the charge data as requested The unit will display the charge data for checking To begin the charge select STAR...

Страница 21: ...city calculated as follows The parameters required for this mode are as follows Target Volts This is the point at which the discharge will stop Discharge Amps This is the constant current amps to disc...

Страница 22: ...ollows Target Volts This is the point at which the discharge will stop Discharge Amps This is the constant current amps to discharge the battery This is usually the A H rating of the battery Test Time...

Страница 23: ...he battery and can be cleared by pressing the CLR key once The parameters required for this mode are as follows Alarm Volts This is the point at which the alarm will sound Discharge Amps This is the c...

Страница 24: ...equested at this point 6 4 3 Capacity Test or Discharge From Previous Data Connect the battery to be discharged and apply power to the unit From the MAIN screen select DISCHARGE followed by PREVIOUS T...

Страница 25: ...ntering data the CLR will backspace any wrongly entered values If the data field is empty i e cursor in first location the whole data entry process will be aborted and the charger will take you back t...

Страница 26: ...n it can be indication of internal plate failure and potential overheating This value of time will stop the charge if the time elapses before the Target Voltage is achieved If not required set to zero...

Страница 27: ...ntered Charge Amps 1 Amps Constant current step 1 current Charge Time 1 Hours and Minutes Constant current step 1 charge duration Charge Amps 2 Amps Constant current step 2 current Charge Time 2 Hours...

Страница 28: ...Target Volts Volts The target volts is the discharged voltage that the charge should stop the discharge and report the battery capacity Discharge Amps Amps This is the constant current discharge amps...

Страница 29: ...n Nominal Volts Volts The battery nominal voltage is used to determine what power rating is required for discharge and also the help validate the data entered Alarm Volts Volts When the battery voltag...

Страница 30: ...can be muted by pressing the CLR key once ALARM CONTINUE At the end of the current step the alarm will sound and continue to sound until it is muted by pressing CLR once At the end of each step result...

Страница 31: ...ack one step Once step 1 is reached it will then revert back to the last empty step or step 6 Selecting CLR STEP will cause the current process step to be cleared If a step is cleared the steps that f...

Страница 32: ...ed normally but under certain conditions the unit will stop the process if these conditions which are not a successful charge or capacity test The following are termination conditions which will cause...

Страница 33: ...and the SHUNT60A or equivalent 60A 60mV shunt 9 2 Calibration Equipment Connection 9 3 Check Procedure Once per year the following calibration procedure should be applied Connect a good quality 24V ba...

Страница 34: ...check has been performed and the unit is out of tolerance then a calibration adjustment will need to be performed the following procedure needs to be observed in order to perform a calibration adjust...

Страница 35: ...e followed whenever a different set of leads is used with the IC8A to ensure that the small drop in voltage is catered for because generally the leads are a fairly small cross sectional area and at hi...

Страница 36: ...Applies to all capacity test modes It indicates that the Discharge Time has been reached or in CAPACITY TEST TARGET an indication that the Target Voltage has been met DISCHARGE COMPLETED Applies to a...

Страница 37: ...the backup battery Replace battery as described in the SERVICE section found elsewhere in this manual Note after battery replacement the unit will require recalibration CAPTEST AMPS EXCEEDED This is a...

Страница 38: ...CELL BELOW TARGET This code will be displayed when a cell monitor discharge which is used to obtain low cell values has been executed and has terminated with one or more cells below the target value 1...

Страница 39: ...r can be included in the printed report This is requested from the operator when START or DELAYED START is selected By default the serial number on print option is turned off To turn the request and p...

Страница 40: ...ilable the use of pipe cleaners or similar must be employed to clear the dust built up Observe all safety precautions when using high pressure air Wear ear defenders and safety goggles and do not poin...

Страница 41: ...the outer most of the two buttons sideways toward the other button using thumb or forefinger see Figure 1 This will release the latch and the door can be swung outwards to expose the paper roll 11 4 2...

Страница 42: ...past the retention button onto the spindle with the paper un spooling in an anticlockwise direction when viewed from the open end see Figure 4 Press the paper feed actuator arm button until the mechan...

Страница 43: ...lockwise by using fingernail see Figure 8 If there is some paper protruding from the front of the printer mechanism ensure that it will pass clearly though the guide channel and past the tear bar befo...

Страница 44: ...discharging may need to be de rated at high ambient temperatures Humidity 5 95 Non condensing Altitude 0 to 3000 Metres Charge Specifications Max Output Volts Max Output Amps Max Output Watts 38 0V 12...

Страница 45: ...ous substances and avoid the increasing landfill Product disposal instructions for residential users When you have no further use for it please remove any batteries and dispose of them and the product...

Страница 46: ...d fully comply with all procedures shown in the literature and product training familiarisation sessions as misuse or failure to follow the instructions may render this warranty void This warranty is...

Отзывы: