FLX-64 Installation Guide
16
Connect Ground
A ground screw is located on the bottom right rear of the matrix to help eliminate static shock during installation
of the matrix. Connect a wire from the matrix to an earth ground.
Connect Sources
HDBaseT Cabling Requirements
HDMI Inputs
HDBaseT Inputs
Connect the source devices to HDMI inputs using HDMI cables that
are less than or equal to 5 meters in length. For source devices that
are further away, an HDMI extension device will be required to
complete the connection.
For all HDBaseT cabling, the EIA/TIA-568B crimp pattern must be used on Category 6 or greater cable. In
areas with large amounts of electromagnetic (EM) or radio frequency (RF) interference, a shielded variety of
Category 5e or greater cable is recommended with shielded connectors on both ends of the selected cable.
Connect the HDBaseT transmitter to the source device per the
manufacturer’s instructions. Connect the HDBaseT cable to the
matrix and the HDBaseT receiver.
TIA/EIA-568B
Orange/White
Orange
Green/White
Blue
Blue/White
Green
Brown/White
Brown
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
1
8
The HDBaseT ports provide 15 watts of Power over Ethernet to 48 volt based HDBaseT devices, which eliminates
the need for a power supply with a compatible HDBaseT device. All Intelix branded HDBaseT transmitters and
receivers that accept remote power are compatible with the FLX-64.