Power supply Subsystem
SPSH4 Server System External Product Specification
Revision
1.11
18
•
The power LED is green and blinks to indicate that AC is applied to the power supply and
+5VSB standby output voltage is available. This LED will turn a solid green to indicate the
power supply is on and all the power output voltages are available.
•
The predictive fail LED blinks amber LED and indicates the power supply will fail in the near
future due to a poorly performing fan.
•
The fail LED is amber and indicates that the power supply has experienced a failure of some
type.
When the power supply configuration changes, the SDR utility must be run so that server
management will properly monitor the new configuration.
A power LED on the front panel, labeled PWR, is green when power is applied to the system.
Table 3 describes the conditions of the LEDs for the power supply.
Table 3: LED Indicators
Power supply LEDs
Power supply Condition
Power LED
(green)
Predictive Fail LED
(amber)
Fail LED
(amber)
No AC power to all PSU
OFF
OFF
OFF
No AC power to this PSU only
OFF
OFF
ON
AC present / Standby Outputs On
Blinking
OFF
OFF
Power supply DC outputs ON and OK
ON
OFF
OFF
Power supply failure
OFF
OFF
ON
Current limit
ON
OFF
Blinking
Predictive failure
ON
Blinking/Latched
OFF
4.1 Mechanical
Dimensions
Mechanical drawings and dimensions, in millimeters, for the power supply are shown in the
Figure 10 below. The power supply has a handle that pivots to assist insertion and extraction
and provides retention.