Sensor Name
Se
ns
or #
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value /
Offsets
EventData
Rearm
Sta
ndby
Tach Fan 6
45h
Fan
04h
Threshold
01h
[u,l][nr,c,nc]
As & De
Analog
R, T
M
–
Fan Redundancy
4Ah
Fan
04h
Discrete
0Bh
Redundancy
Regained
Redundancy lost
Redundancy
Degraded
Non-red:Suff res
from redund
Non-red:Suff res
from insuff res
Non-red:Insuff res
Redundancy
Degraded from full
redundancy
Redundancy
Degraded from
non-redundant
As –
Trig
Offset
A
X
Fan 1 Presence
4Bh
Slot/Connector
21h
Sensor
Specific
6Fh
Device installed
As & De
–
Trig Offset
A
–
Fan 2 Presence
4Ch
Slot/Connector
21h
Sensor
Specific
6Fh
Device installed
As & De
–
Trig Offset
A
–
Fan 3 Presence
4Dh
Slot/Connector
21h
Sensor
Specific
6Fh
Device installed
As & De
–
Trig Offset
A
–
Fan 4 Presence
4Eh
Slot/Connector
21h
Sensor
Specific
6Fh
Device installed
As & De
–
Trig Offset
A
–
LVDS SCSI
channel 1
terminator fault
60h
Terminator
1Ch
Digital
Discrete
06h
Performance Met
or Lags
As –
Trig
Offset
A
–
LVDS SCSI
channel 2
terminator fault
61h
Terminator
1Ch
Digital
Discrete
06h
Performance Met
or Lags
As –
Trig
Offset
A
–
Power Supply
Status 1
70h
Power Supply
08h
Sensor
Specific
6Fh
Presence
Failure
Predictive Fail
A/C Lost
As & De
–
Trig Offset
A
X
Power Supply
Status 2
71h
Power Supply
08h
Sensor
Specific
6Fh
Presence
Failure
Predictive Fail
A/C Lost
As & De
–
Trig Offset
A
X
Power Nozzle
Power Supply 1
78h
Current
03h
Threshold
01h
[u,l][ nr,c,nc]
As & De
Analog
R, T
A
–