Intel® Server Board S3420GP TPS
Server Management Capability for Intel® Server Board S3420GPV
Revision 2.4
Intel order number E65697-010
45
Setup Item
Comments
CPU Fan PWM
Get and display CPU fan PWM periodically
System Fan PWM
Get and display system fan PWM periodically
System temperature
Get and display current system temperature
monitored by system sensor
+Vccp
Get and dVccp voltage periodically
+12V
Get and d12 voltage periodically
+3.3V
Get and d3.3 voltage periodically
+5.0V
Get and d5.0V voltage periodically
+1.5V
Get and d1.5V voltage periodically
+1.05V
Get and d1.05 voltage periodically
+3.3V(standby)
Get and d3.3V(standby)voltage periodically
5.2
SMBIOS
5.2.1
Data Storage
On Intel
®
Server Board S3420GPLX and Intel
®
Server Board S3420GPLC with iBMC, the
SMBIOS type 1, 2, 3 are from FRUSDR by BMC. But on Intel
®
Server Board S3420GPV,
SMBIOS type 1, 2, 3 are stored in BIOS flash during manufactory build, so it’s also non-volatile
data storage.
BIOS retrieve the SMBIOS data from flash during POST, and it builds the SMBIOS type 1, 2, 3
into SMBIOS table and then transfers the control to operating system. Operating system and
system management software can use the SMBIOS table for system management purpose.
5.3
Event log and Viewer
5.3.1
Event Log Viewer in Setup
On Intel
®
Server Board S3420GPLX and Intel
®
Server Board S3420GPLC, there is a dedicated
utility to view the event log. There is no IPMI support - the way to view the event log in BIOS
Setup, on Intel
®
Server Board S3420GPV.
There is one page in BIOS setup for event log viewer. It is located in Error Manager Page.