44
Setup Item
Options
Help Text
Comments
CPU Fan Altitude
300m/
900m
/1500m/3000m
Select CPU FAN default PWM
according to altitude under Auto
mode
System Fan Altitude
300m/
900m
/1500m/3000m
Select Board Fan default PWM
according to altitude under Auto
mode
Hysteresis
2 Degree Celsius
3 Degree Celsius
4 Degree Celsius
Hysteresis – is used to smoothing
the FAN speed transition when
temperature approaching
temperature target upward or
downward. Select Hysteresis to
keep FAN at the same speed
within the range
Default Fan PWM
40%
60%
80%
100%
Select Default FAN PWM to make
FAN speed keep the invariable
speed when temperature is below
FSC temperature target at low
customized conditions. This
delivers optimized acoustic level
The change can
not take effect
immediately by
increasing the
PWM. It requires
a power cycle or
a thermal event
to take the
change in effect.
Note
: the two options of Hysteresis and Default Fan PWM apply to all the four Fans
5.1.4
Voltage and Temperature Status Screen
Display monitored voltage, current Fan speed PWM and temperature
Server Management
Real time Temperature and PWM:
CPU Fan PWM
System Fan PWM
System temperature
Voltage status:
+Vccp
+12V
+3.3V
+5.0V
+1.5V
+1.05V
+3.3V(standby)
Figure 17. Setup Utility — Voltage and Temperature Status Screen
Table 15. Setup Utility — Voltage and Temperature Status Fields