Appendix B: BMC Sensor Tables
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Revision 1.1
Intel order number G34153-003
140
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 4
DIMM
Aggregate
Thermal Margin
1
(P4 DIMM Thrm
Mrgn1)
B6h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
–
Processor 4
DIMM
Aggregate
Thermal Margin
2
(P4 DIMM Thrm
Mrgn2)
B7h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
–
Fan
Tachometer
Sensors
(Chassis
specific
sensor names)
BAh
–
BFh
Chassis and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
2
As and De
Analog
R, T
M
-
Processor 1
DIMM
Thermal Trip
(P1 Mem Thrm
Trip)
C0h
All
Memory
0Ch
Digital Discrete
03h
0A- Critical
overtemperature
Fatal
As and De
–
Trig
Offset
M
-
Processor 2
DIMM
Thermal Trip
(P2 Mem Thrm
Trip)
C1h
All
Memory
0Ch
Digital Discrete
03h
0A- Critical
overtemperature
Fatal
As and De
–
Trig
Offset
M
-
Processor 3
DIMM
Thermal Trip
(P3 Mem Thrm
Trip)
C2h
All
Memory
0Ch
Digital Discrete
03h
0A- Critical
overtemperature
Fatal
As and De
–
Trig
Offset
M